Remko rvd...dc, Technical data – REMKO RVD 351 DC User Manual

Page 30

Advertising
background image

Technical data

Range

RVD 351DC

RVD 521DC

Operational mode

Cooling / heating

Nominal cooling output

1)

kW

3.52 (1.41 to 4.11)

5.27 (1.59 to 5.65)

Nominal heating output

2)

kW

4.29 (1.43 to 4.83)

5.86 (1.45 to 6.15)

Energy efficiency class, cooling

1)

A

A

Energy efficiency ratio EER

1)

3,32

3,25

Energy efficiency class, heating

2)

A

A

Coefficient of performance COP

2)

3,61

3,80

Power consumption, annual, (500h) C/H

410 / 560

810 / 770

Operating range (room volume), approx.

110

160

Coolant

410A

4)

Power supply

V / Hz

230/1~/50 Hz

Nom. electrical power consumption, cooling

1)

kW

1,06 (0,41-1,45)

1,62(0,56-2,63)

Nom. electrical power consumption, heating

2)

kW

1,19 (0,38-1,88)

1,54 (0,72-2,65)

Electr. rated power consumption

kW

1,90

2,60

Electr. nominal power consumption cooling

1)

A

4,34 (2,02-12,24)

7,08 (2,43-12,35)

Electr. nominal power consumption heating

2)

A

6,64(2,06-12,03)

6,82 (3,13-12,32)

Electr. starting current, max.

A

12,0

12,0

Coolant connection - injection line

Inches

(mm)

1/4 (6,35)

1/4 (6,35)

Coolant connection - suction line

Inches

(mm)

1/2 (12,70)

1/2 (12,70)

Max. operating pressure

kPa

4200

Corresponding

indoor unit

RVD 351DC IT

RVD 521DC IT

Adjustment range, room temperature

°C

+17-+30

Operating range

°C

+17-+31

Air flow volume per speed setting

m³/h

510/530/680

560/710/800

Sound pressure level per speed setting

3)

dB(A)

33/37/40

37/40/42

Protection degree

IP

X0

Condensate drain

mm

25

Condensate pump, flow rate, max.

mmWS

500

750

Dimensions - height

mm

255

Width

mm

580

Depth

mm

580

Dimensions Cover length / width

mm

650 / 650

Weight

kg

21,0

Corresponding

outdoor component

RVD 351DC AT

RVD 521DC AT

Operating range - cooling

°C

+5 - +43

+5 - +43

Operating range - heating

°C

-5 - +24

-5 - +24

Air flow rate, max.

m³/h

2400

Protection degree

IP

24

Noise output max.

3)

dB(A)

48

52

Refrigerant, basic quantity

kg

1,40

1,70

Refrigerant, additional quantity > 5 m

g/m

30

30

Refrigerant pipe, max. length

m

15

20

Refrigerant pipe, height indoor unit and out-

door unit max.

m

10

10

Dimensions - height

mm

590

700

Width

mm

760

845

Depth

mm

280

310

Weight

kg

41,0

63,0

Serial number

548...

549...

EDP no.

1623160

1623170

1) Air intake temp. TK 27°C / FK 19°C, outdoor temp. TK 35°C / FK 24°C, max. air volume, 5m pipe length in combination with MVT 900 / 950 DC
2) Air intake temperature TK 20°C outdoor temperature TK 7°C, FK 6°C, max. air volume, 5m pipe length in combination with MVT 900 / 950 DC
3) Gap 1 m free space 4) Contains greenhouse gas according to Kyoto protocol