Dehumidification MODE

It is recommended that the target temperature be set to 24°C in

dehumidifying mode. Due to the low temperature of the refrigerant, the

dew point of the air at the condenser is undercut. The excess moisture in

the air is condensed by the vaporiser, the room is dehumidified.

DEHUMIDIFICATION
MODE

MODE

HEATING Mode

In the heating mode, you can heat the room in spring or fall. The selected
room temperature is set using the

▲/▼ keys in 1 °C increments. If the

room temperature is 1 °C below the selected target temperature, the

indoor unit starts to heat the air in the room. If the set room temperature
is exceeded by approx. 1 °C, the controller will switch off the heater

function. To protect the compressor, the controller will wait 3 minutes

before switching on the heating mode again.

MODE

HEATING
OPERATION

Cooling MODE

In cooling mode, the air in the room is cooled down to the adjusted
nominal temperature. The desired room temperature is set with the

▲/▼

keys in 1 °C increments. If the room temperature is 0.5 °C above the

selected nominal temperature, then the interior unit starts to cool down

the air in the room. If the temperature falls to approx. 1 °C below the set

room temperature, the controller will switch off the cooling function. To

protect the compressor, the controller only turns cooling on again after a

waiting period of 3 minutes.

COOLING
OPERATION

MODE

REMKO RVD...DC

10