Unit description – REMKO CLK 80-RV User Manual

Page 5

Advertising
background image

5

Locations at which units are
used

As mobile, directly fired fan-
assisted heaters, the units deliver
instant heat.
They are designed exclusively for
commercial use, with and without
warm air hoses.

The units may be used for the
heating, temperature adjustment
or drying of:

Warehouses

Exhibition halls

Trade fairs

Lightweight construction halls

Large tents / marquees

Large construction sites

Building drying

Unit description

The units are portable, directly
fired fan-assisted heaters (WLE)
with heat exchanger and exhaust
gas connections exclusively for
commercial applications.

The units are directly fired with EL
heating oil or Diesel fuel.

The units can be operated with
or without exhaust gas pipe
(depending on the conditions
on the customer's side).
They have been designed for
universal and straightforward use.

The units must be exclusively
operated with separate type-
approved forced-air WLE-type
burners.

The units are equipped with
a noise-optimised and low-
maintenance, high performance
radial fan, a room thermostat
receptacle and a mains cable with
a 230 V shock-proof plug or CLK
170-RV with 400 V CEE connector.

The CLK 170-RV units are
equipped with a device for
automatically checking the
turning direction of the fan motor,
as standard.

With factory fitted forced-air oil
burners the CLK 170-RV units
have integrated REMKO Multiflex
oil pre-heating fitted as standard.
With the CLK 80-RV this
is available as an option
(EDP no. 1071411) .

The units conform
to the fundamental health
and safety requirements
of the appropriate EU stipulations
and are simple to operate.

Operating sequence

If the units are set to heating
mode, then the forced-air burner
starts automatically. In fully
automatic heating mode with
room thermostat the forced-air
burner starts only when heat
is required.

After the burner has run for a short
time the temperature controller
"TR" (target temperature
ca. 40°C) switches the supply air
fan on automatically.
Warm air is blown out.

When operating with a room
thermostat this process is
repeated automatically depending
on the heat demand.

The temperature monitor "TW"
(target temperature 80 to 85°C)
monitors the internal temperature
of the unit.

After switching off the units via
the operating switch or the room
thermostats the supply air fan runs
to cool the combustion chamber
with the heat exchanger for
a certain time and then switches
off automatically.
This process may be repeated
several times if necessary,
depending on the temperature
profile.

In simple ventilating mode the
unit can be used to recirculate the
air permanently.
Thermostatic control is not possible
in this case.