Fig. 4: Distance between the holes

6.

Hang the fresh water module onto the

screws. Tighten the screws so that the insu-

lation on the sides is flush to the wall.

7.

Connect the pipes of the fresh water module

to the system in accordance with Fig. 5.

1. Secondary side:

Hot water outlet,

Connection ¾" AG, flat-sealing

2. Primary side:

Inlet from buffer tank, ¾" IG,

Piping at least DN 20 22 x 1 mm,

recommended DN 25 28 x 1.5 mm

3. Primary side:

Return flow to buffer tank, ¾" IG,

Piping at least DN 20 22 x 1 mm,

recommended DN 25 28 x 1.5 mm

4. Secondary side:

Cold water inlet,

Connection ¾" AG, flat-sealing

A

B

Fig. 5: Piping of the fresh water station

A: Pipe distance from the wall

(secondary) = 107 mm

B: Pipe distance from the wall (primary) = 67 mm