15

16

Note: Explanations of Swing and Differential set point

HEAT mode: thermostat controls the temperature according to the following

diagram

o o

o

Example for Heating: (Set point = 70 F, Swing = 1 F, Differential = 2 F)

o o

=> 1st stage heater turns on when room temp is 69 F and off at 71 F.

o o

=> 2nd stage heater turns on when room temp is 67 F and off at 70 F.

LCD indication

Step

Procedure / Description

Press "Prog" key once to confirm the setting
and it will go to Advanced Recovery setting.

Press Up/Down key to enable/disable
Advanced Recovery Mode.

9

Press "Prog" key once to confirm the setting
and it will go to the Home page.

10

RECOVERY

RECOVERY

WAKE

AM

MO

FAN AUTO

PROG ON

OFF

Diff

Swing

SD= switch differential

Swing

Temperature

Output

Off

Heat

st

1 Turn off

nd

2 Turn off

Set point

st

1 Turn on

nd

2 Turn on

COOL Mode: thermostat controls the temperature according to the following

diagram

o o

Example for Cooling: (Set point = 80 F, Swing = 1 F)

o o

=> Cooler turns on when room temp is 81 F and off at 79 F.

AUTO:

thermostat controls the temperature according to the following
diagram

o o

There is a dead band 4 F/2 C between heat set point and cool set point.

o

Example 1: If user select heat set point is 70 F, the minimum cool set point will be

o o

limited at "heat set point" + 4 F: 74 F

o o

Pervious heat set point is 70 F and cool set point is 74 F

o

Example 2: If user changes heat set point to 72 F, cool set point will be updated to

o

76 F automatically to maintain the dead band.

Swing

Temperature

Output

Off

Cool

Turn off

Set point

Turn on

Temperature

Output

Off

Heat

st

1 Turn off

nd

2 Turn off

Heat Set point

st

1 Turn on

nd

2 Turn on

Diff

Swing

Swing

Dead band

Cool Set point