Z‐Wave Configuration Parameters   

Different user has different preferred settings of their thermostat, you may use the below configuration 
parameters to change settings of corresponding functionality.   

 

Functions 

Parameter Number Parameter value range 

Swing 

1 (0x01) 

1 (0x01) = 1 

o

F / 0.5 

o

C   

2 (0x02) = 2

 o

F / 1.0 

o

(default) 

3 (0x03) = 3 

o

F / 1.5 

o

C   

4 (0x04) = 4 

o

F / 2.0

 o

C   

Differential 

2 (0x02) 

1 (0x01) = 1 

o

F / 0.5 

o

C   

2 (0x02) = 2

 o

F / 1.0 

o

(default) 

3 (0x03) = 3 

o

F / 1.5 

o

C   

4 (0x04) = 4 

o

F / 2.0

 o

Set filter counter 

3 (0x03) 

500 (0x01F4) to 4000 (0x0FA0) hours   

Default = 500 (0x01F4) hours 

Resolution = 100 (0x0064) hours 

Report filter counter 

(read only) 

4 (0x04) 

0 (0x0000) to 9999 (0x270F) hours 

Scale of temperature 

5 (0x05) 

0 (0x00) = 

o

1 (0x01) = 

o

(default) 

Dead band 

 

(On thermostats that 

automatically control both 

heating and cooling systems, a 

dead band is a temperature 

range in which neither system 

turns on. The dead band 

prevents the thermostat from 

activating heat and cooling in 

rapid succession. This 

conserves energy by providing 

a range of temperatures 

requiring no energy 

consumption) 

 

 

 

 

 

14(0x0E) 

Dead band value: 

3(0x03)= 3

o

F/ 1.5

o

4(0x04)= 4

o

F/ 2.0

o

(default) 

5(0x05)= 5

o

F/ 2.5

o

6(0x06)= 6

o

F/ 3.0

o