Troubleshooting

Most difficulties in audio systems are the re-
sult of incorrect connections, or improper
control settings. If you encounter problems,
isolate the area of the difficulty, check the con-
trol settings, determine the cause of the fault
and make the necessary changes. If you are
unable to get sound from the RCD-961, re-
fer to the suggestions for the following con-
ditions:

Power Indicator Is Not Lit

The Power Indicator and the basic items in
the Display window should be lit whenever
the RCD-961 is plugged into the wall power
outlet and the Power button is pushed in. If it
does not light, test the power outlet with an-
other electrical device, such as a lamp. Be sure
the power outlet being used is not controlled
by a switch that has been turned off.

Specifications

Total Harmonic Distortion + Noise

0.0045% @ 1kHz

Intermodulation Distortion

0.0045% @ 1kHz

Frequency Response (

±

0.5 dB)

20-20,000 Hz

Channel Balance

±

0.5 dB

Phase Linearity

±

0.5 degree

Channel Separation

> 98 dB @ 1kHz

Signal to Noise Ratio

> 100dB

Dynamic Range

> 96 dB

Digital to Analog Converters

18 bit equivalent, multi-level Delta-Sigma DAC with
8x oversampling digital filter and HDCD

Speed Accuracy, Wow & Flutter

Quartz Crystal Precision

Output Impedance

100 Ohms

Digital Output

0.5 Volt, Peak to Peak

Load Impedance

75 Ohms

Power Requirements

USA Version

AC 115V, 60 Hz

European Version:

AC 230V, 50 Hz

Power Consumption

20 Watts

Dimensions (W, H, D)

17

3

/

8

x 2

7

/

8

x 12

7

/

16

inches

440 x 72 x 316 mm

Weight (net)

5.4 kg, 11.9 lb.

All specifications are accurate at the time of printing. Rotel reserves the right to make improvements without
notice.

Rotel and the Rotel HiFi logo are registered trademarks of The Rotel Co, Ltd., Tokyo, Japan.

, HDCD

®

High Definition Compatible Digital

®

and Pacific Microsonics™ are either registered trademarks or

trademarks of Pacific Microsonics, Inc, in the United States and /or other countries.

Fuse Replacement

If another electrical device works when plugged
into the power outlet, but the Power Indica-
tor and the Display still will not light when the
RCD-961 is plugged into the wall outlet, it in-
dicates that the internal power fuse may have
blown. If you believe this has happened, con-
tact your authorized Rotel dealer to get the
fuse replaced.

No Sound

Check the cables between the RCD-961 and
the amplifier inputs to be sure they are con-
nected properly. Be sure the amplifier input
that the RCD-961 is selected. Be sure the tape
monitor system of the amplifier has not been
activated. Check the wiring between the
amplifer and the speakers.