Pin reading device auxiliary serial interface, Network bus termination – Datalogic Scanning CBX500 User Manual

Page 11

Advertising
background image

CBX500

INSTALLATION

MANUAL

11

9-PIN READING DEVICE AUXILIARY SERIAL INTERFACE


The reading device auxiliary serial interface available on the internal CBX500 9-pin connector can be used either
for configuration or for data monitoring.

Connections can be made to a PC or Laptop using a straight through cable or a USB-RS232 converter.

The details of the connector pins are indicated in the following table:

5

1

6

9

Figure 9 - 9-pin D-Sub Female Connector

9-pin Connector Pinout

Pin Name

Function

2 TX

Auxiliary

RS232

3 RX

Auxiliary

RS232

5 SGND Auxiliary

Reference

Ground

1, 4, 6, 7, 8, 9

N.C.



NETWORK BUS TERMINATION


ID-NET™

ON

OFF

Figure 10 – ID-NET™ Termination Resistance Switch


The ID-NET™ termination resistance switch enables or disables the insertion of the bus termination resistor for
ID-NET™ network applications.

CAUTION

In ID-NET™ network applications the termination resistor must be enabled ONLY on the first
and last devices of the chain. On all the other devices this resistor MUST NOT be enabled
(OFF).