Specifications

This ice machine is designed to be used indoors, in
a controlled environment, and under limited
conditions (see page 1), outdoors. It can be used in
a wide variety of environmental conditions, but
there are limits. Use outside of the listed limitations
is misuse and will void the warranty.

Air temperature limits:

The ice machine will operate adequately within the
limits, but functions best in temperatures between
70 and 80 degrees F.

Minimum – 50 degrees F. (10

o

C)

Maximum – 100 degrees F. (38

o

C)

Water temperature limits:

Minimum – 40 degrees F. (4.5

o

C)

Maximum – 100 degrees F. (38

o

C)

Water pressure limits:

Minimum – 20 psi (1.4 bar)

Maximum – 80 psi (5.5 bar)

Because the ice machine is making a food product,
the water supply to the ice machine must be
potable, or fit for human consumption.

Other:

Indoor use and kickplate: You may remove the
stainless steel kickplate cover from the unit when
installed indoors. Leave the plastic kickplate on the
unit.

Note:The stainless steel kickplate cover must
remain on the unit when the unit is installed
outdoors.

Electrical voltage limits:

Minimum - 104 volts

Maximum – 126 volts

Models

CU50GA-1A - gravity drain

CU50PA-1A - pump drain

Options:

Kickplate Extension: In some situations the leg
levelers will be extended enough to become visible.
A kit to extend the kickplate over the legs is KKPF.

Cabinet Stability: In some free standing
installations it may be prudent to add a bracket that
secures the back of the cabinet to a wall. That kit
number is KATB.

Drain Conversion: A gravity drain model can be
converted to a drain pump model by installing a
drain pump kit. The drain pump kit consists of a
drain pump, wiring harness and associated tubing.
The part number is A39462-021.

Warranty Information

Warranty information is supplied separately from
this manual. Refer to it for coverage. In general, the
warranty covers defects in materials or
workmanship and does not cover corrections of
installation errors or maintenance.

May 2010

Page 2

CU50

Installation and User's Manual

Cabinet Dimensions

Width

Depth, with door panel, handle adds 1 5/8"

Height

14 7/8"

22 3/4"

33 3/8" to 34 3/8"

Advertising