Test procedures – Scotsman HID312 Service Manual User Manual

Page 27

Advertising
background image

HID312, HID525, HID540

Service Manual

April 2015

Page 27

Test Procedures

Dispensing Sensors
Remove upper front panel, check controller indicator lights.

Dispense sensor

and system Test

Does Proper

Dispensed Sensor

Light Glow?

Hold Opaque

Container in Front

of Sensor

Attach voltmeter to

valve or motor,

push correct

Dispense button

and confirm

voltage.

Does motor or

water valve

activate?

No

Sensor is working.

Continue test.

Voltage

Correct?

Replace controler

Replace motor or

valve.

Yes

Yes

Ice or water

dispensed?

Yes

System Passed

Test

Yes

Replace Sensor

Push proper

dispense button, its

dispensed light is

ON.

No

Does motor or

water valve

activate?

No

Check for other

causes

No

Yes

No

Advertising