Scotsman CME256 AutoIQ User Manual

Introduction

Advertising
background image

Introduction:

This product manual contains the information
needed for the setup, installation, initial start up,
sanitation and maintenance of this ice machine.
Keep it for future reference.

All series of these 4 models are covered in this
manual:

CME256, a 115 volt, single evaporator
machine

CME506, a 115 volt, dual evaporator
machine (115 volt if 60 Hz, 230 volt if 50 Hz)

CME656 and CME806, 230 volt, dual
evaporator machines

Be certain that the information applies to the
model in question. If no model is listed, the
information applies to all models, including A
through H series.

This manual is organized in the same way as the
expected use of the machine, it begins with
specifications, goes thru unpacking and setup,
shows where everything is; continues with initial
start up, then describes how it works. After that is
the sanitation section, followed by service
diagnosis and repair.

CME256, 506, 656, 806: AutoIQ™ Cubers

June 2007

Page 1

Printed on Recycled Paper.

Parts lists are in the center section.

Table of Contents

Specifications: . . . . . . . . . . . . . . . . . page 2

Pre-Installation

. . . . . . . . . . . . . . . . page 3

Location & Assembly: . . . . . . . . . . . . . page 4

Stacking:

. . . . . . . . . . . . . . . . . . . page 5

Plumbing: . . . . . . . . . . . . . . . . . . . page 6

Electrical: . . . . . . . . . . . . . . . . . . . page 7

After Utility Connections: . . . . . . . . . . . page 8

Component Location and Function: . . . . . . page 9

AutoIQ Controller: . . . . . . . . . . . . . . . page 10

Initial Start Up: . . . . . . . . . . . . . . . . . page 11

Adjustments:

. . . . . . . . . . . . . . . . . page 12

Adjustments:

. . . . . . . . . . . . . . . . . page 13

How To Operate The AutoIQ Controller

. . . page 14

How The Electronic Cuber Works . . . . . . . page 15

Technicians Only: Freeze Cycle Operational Sequence

. . . . . . . . . . . . . . . . . . . . . . . . . page 16

Technicians Only: Harvest Cycle Operational Sequence

. . . . . . . . . . . . . . . . . . . . . . . . . page 17

Sanitation and Cleaning . . . . . . . . . . . . page 18

Additional Maintenance . . . . . . . . . . . . page 19

Additional Maintenance: Water Distributors

. page 20

Additional Maintenance: Inlet Water Valve Screen

. . . . . . . . . . . . . . . . . . . . . . . . . page 21

Additional Maintenance: Bin Controls, Condenser

. . . . . . . . . . . . . . . . . . . . . . . . . page 22

Service Diagnosis: Controller Diagnostic Light Analysis

. . . . . . . . . . . . . . . . . . . . . . . . . page 23

Service Diagnosis . . . . . . . . . . . . . . . page 24

Service Diagnosis: Components . . . . . . . page 25

PTCR Diagnosis

. . . . . . . . . . . . . . . page 26

Operational Characteristics: CME256

. . . . page 27

Operational Characteristics: CME506

. . . . page 28

Operational Characteristics: CME656

. . . . page 29

Operational Characteristics: CME806

. . . . page 30

Removal and Replacement . . . . . . . . . . page 31

Removal and Replacement . . . . . . . . . . page 32

Removal and Replacement: Sensors . . . . . page 33

Removal and Replacement: Fan Blade and/or Fan
Motor

. . . . . . . . . . . . . . . . . . . . . page 34

Access Valves: . . . . . . . . . . . . . . . . page 35

Before Calling for Service . . . . . . . . . . . page 36

Advertising