Fm2400rh, Circuit board testing – Scotsman FM2400RH User Manual

Page 27

Advertising
background image

Water Level
1. Unplug “water sen” connector from control
board.
2. Plug “water sen” connector from Scotsman
tester into circuit board.

a. Move “water” switch on tester to No Water

position. The No Water light on the circuit board
should go ON. If not, replace the circuit board.

b. Move the “water” switch on the tester to the

Water position. The No Water light on the board

should go OFF. If not replace the circuit board. If
the light does go off, replace the water level sensor.
If the Bin Empty light is ON, wait 10-20 seconds for
the machine to start. The machine should start.

LIGHT ON

WATER SENS

SWITCH TO

"NO WATER"

SWITCH TO

"WATER"

LIGHT OFF

CIRCUIT BOARD TESTING

FM2400RH

August 1994