Mar1400 4, Mar1400 – Scotsman MAR1400 User Manual

Page 4

Advertising
background image

MAR1400

Set for Fresh water Operation
IMPORTANT OPERATING REQUIREMENTS:
WATER LEVEL IN DRUM RESERVOIR

115-120 mm (4.5 to 4.75 inches)

DRUM ROTATING SPEED

1.5 RPM (thick ice)

2.3 RPM (thin ice)

REFRIGERANT:

R-404A

REQUIRED CONDENSING CAPACITY

4800 Kcal/h at -24EC Evap. Temp. (19,000

BTUH at -11

o

F)

WATER PRESSURE CONTROL SETTING

0.8 Bar (11 PSIG)

MAX. WATER TEMPERATURE

35 °C (95

o

F)

MIN. WATER TEMPERATURE

5 °C (41

o

F)

MIN. WATER PRESSURE

1 atm. (15 PSI)

MAX. WATER PRESSURE

5 atm. (75 PSI)

MIN. AMBIENT TEMPERATURE

5 °C (41

o

F)

MAX. AMBIENT TEMPERATURE

40 °C (104

o

F)

MAX. VOLTAGE VARIATION

± 10%

Suggested Condensing Unit Settings:

HEAD PRESSURE SETTING

15 Bar (218 PSIG) on air cooled and water

cooled units

LOW PRESSURE SETTING

1.6 Bar (23 PSIG) on air cooled units

HI-PRESSURE CONTROL SETTING

36 Bar (522 PSIG)

LO-PRESSURE CONTROL SETTING

0.2 Bar (3 PSIG)

MAR1400 & MAR2000

December 2000

Page 4

Advertising