Control box, Electrical system – DENSO CORPORATION CLASSIC PLUS 26 User Manual

Page 24

Advertising
background image

ELECTRICAL SYSTEM

16

2.

Control Box

A. Capacitors

The capacitors are used to temporarily boost
the power output available to the fan motor
and the compressor at start-up.

The specifications of each capacitor are listed
below:

CAPACITOR

VOLTAGE CAPACITANCE

APPLICATION

RATING

(

µ

f)

Fan Motor

440

12.5

Compressor

370

40

B. Relay Board

The Relay Board receives signals and outputs
from the control board that contains a micro-
processor. The relay board contains the
compressor, fan on and fan mode (speed)
relays. It also contains a step-down trans-
former that converts the line voltage (208/230
VAC) to 12 volts. This is then converted from
AC to DC and used for relay coil activation.
The 12V (DC) power is sent to the Control
Panel Assembly where it is further reduced to
5 volts for the system logic.

The relay board also contains the DIP-Switch.
The DIP-Switch is used to change the Fan
Mode operation from Stop to Operate and
change the Set Point temperature display
from ˚F to ˚C.

NOTE: The r elay boar d must be ser viced as a com-
plete assembly . It has only one ser viceable compo-
nent, the fuse.

(a) Relay Board Fuse

NOTE: The r elay boar d fuse is the only ser viceable
component on the r elay boar d assembly .

This fuse provides protection against damage
to the step-down transformer. It must be
replaced with the exact type of fuse or an
equivalent.

Fuse Specifications: 2/10A 250V

ƽCAUTION: Failure to use the exact type of fuse
could result in damage to the unit and/or to com-
ponents. It will

also void the warranty of the unit.

Compressor
Capacitor

Fan Motor
Capacitor

Terminal Block

Relay Board

Relay Board Fuse

DIP Switch

S1

CF

ST

OP

OPERA

TE

J9

Temperature Scale Display Switch

˚

C

˚

F

DIP Switch

Fan Mode Control Switch

STOP OPERATE

Relay Board Fuse

Relay Board

Control Box

DIP Switch

Advertising