SL Power Electronics GLC110 User Manual

Glc110 series installation instructions, Warning! risk of fire

Advertising
background image

SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com

MODEL NUMBERS: GLC110-X, where X = 12, 15, 24, 212, 215, or 524. May be followed by suffix –L to indicate
optional chassis or –LC to indicate chassis/cover and/or suffix –XXX where XXX may be any number from 001 thru 999 to
indicate value added configurations that have no impact on safety and/or suffix G to indicate compliance to RoHS.

RATINGS:

Input: 100-240 V ac, 2.9 A, 50/60 Hz
Output:

Notes:

1. Wattage ratings are maximum continuous power, total of all outputs at ambient of 50 °C.
2. Maximum Operating Relative Humidity 96 %, no condensation.
3. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.

SAFETY DECLARATION: SL Power Electronics, Corp. (SLPE). declares under our sole responsibility that
all models listed above are in conformity with the applicable requirements of EN 60950-1 following the
provisions of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the

applicable requirements of UL 60950-1, CSA 22.2 No. 60950-1 (L3M1), and EN 60950-1 for Pollution Degree 2
environment and Class I TN-S power systems. The outputs of the supplies meet the requirements for SELV and are not an
energy hazard.

Protection Class I requires that the ground terminal be bonded to Protective Earth in the end application. Using this terminal
for the primary system earthing terminal is not recommended.

Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the applicable safety
standards, must be maintained after installation to preserve the intended safety.

The maximum operating temperatures of certain safety components, as defined in the applicable safety standards, must not be
exceeded after installation to preserve the intended safety. The output power, ambient air
temperature and the availability, amount, direction and/or restriction of airflow influence the
temperatures of these components.

WARNING! RISK OF FIRE!

A blown fuse is an indication of catastrophic failure of circuit component(s). Repair must
be performed by Condor authorized personnel. Fuse F1 must be replaced with F 3.15A
250V, IEC 60127-2 type.

C O N N E C T I O N S

Single Output Models

Multi-Output Models

J1 Pin

AC Input

J2 Pin

DC Output

J2 Pin

DC Output

J2 Pin

DC Output

J2 Pin

DC Output

1

Ground

1

+ Output

8

Return

1

Output #1

8

Common

3

Neutral

2

+ Output

9

Return

2

Output #1

9

Common

5

Line

3

+ Output

10

Power Fail

3

Output #1

10

Power Fail

4

+ Output

11

N/C

4

Output #1

11

N/C

5

Return

12

N/C

5

Common

12

Output #2 (-)

6

Return

13

N/C

6

Common

13

Output #2 (+)

7

Return

7

Common

MATING CONNECTORS

CAUTION:

J1 Amp/Tyco Housing 640250-5 Contact 640706-1

Do not exceed 5 A per contact.

J2 Amp/Tyco Housing 1-640250-3 Contact 640706-1

SLPE. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized agents of
SLPE., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, EN, and IEC safety standards.

41-34676-0001 Rev. E 6/19/07

GLC110 SERIES

INSTALLATION INSTRUCTIONS

0 CFM

0 CFM

26 CFM

60 Watts Max

75 Watts Max

110 Watts Max

MODEL

Output

Volts

With Cover

Without Cover

With or without cover

GLC110-12

#1

12

5.0 A

6.3 A

9.1 A

GLC110-15

#1

15

4.0 A

5.0 A

7.3 A

GLC110-24

#1

24

2.5 A

3.2 A

4.6 A

GLC110-212

#1

+12

5.0 A

6.3 A

9.1 A

#2

-12

2.5 A

2.5 A

3.0 A

GLC110-215

#1

+15

4.0 A

5.0 A

7.3 A

#2

−15

2.5 A

2.5 A

3.0 A

GLC110-524

#1

+24

2.5 A

3.2 A

4.6 A

#2

+5

1.5 A

1.5 A

2.0 A

Attention, Consult
Accompanying Documents

Alternating Current

Attention, Dangerous Voltages

Earth (Ground)

EXPLANATION OF SYMBOLS

Direct Current

Advertising