RATINGS:

Input: 100-240 V ac, 1.3 A, 50/60 Hz
Output: 40 W max or see table for standard output voltage models.

Model

Watts

1

Output #1

Output #2

Output #3

GLC40A

40

+5.1 V dc, 3 A

+12 V dc, 2 A

-12 V dc, 0.3 A

GLC40B

40

+5.1 V dc, 3 A

+15 V dc, 2 A

-15 V dc, 0.3 A

GLC40D

40

+5.1 V dc, 3 A

+24 V dc, 1 A

-12 V dc, 0.3 A

GLC40-3.3

26.4

3.3 V dc, 8 A

Notes:

GLC40-5

40

5.0 V dc, 8 A

1. Maximum continuous output power at 50 °C - Total of all Outputs.

GLC40-9

40

9.0 V dc, 4.4 A

GLC40-12

40

12.0 V dc, 3.3 A

2. Maximum Relative Humidity 96 %, no condensation.

GLC40-15

40

15.0 V dc, 2.7 A

GLC40-24

40

24.0 V dc, 1.7 A

3. Storage: -40 to +85 °C. Units should be allowed to warm-up

GLC40-28

40

28.0 V dc ,1.4 A

under non-condensing conditions before application of power.

GLC40-48

40

48.0 V dc, 0.83 A

SAFETY DECLARATION: SL Power Electronics Corp. declares under our sole responsibility that all models
listed above are in conformity with the applicable requirements of EN60950-1 following the provisions of the
Low Voltage Directive 73/23/EEC.

All models are Certified to be in compliance with the applicable

requirements of UL 60950, CSA 22.2 No. 60950 (L3M1), and EN 60950-1 for Pollution Degree 2 environment

and Class I TN-S power systems. The outputs of the supplies meet the requirements for SELV and are not an energy hazard.

Protection Class I requires that the ground terminal be bonded to Protective Earth in the end application. Using this terminal
for the primary system earthing terminal is not recommended.

Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the applicable safety
standards, must be maintained after installation to preserve the intended safety.

The maximum operating temperatures of certain safety components, as defined in the
applicable safety standards, must not be exceeded after installation to preserve the
intended safety. The output power, ambient air temperature and the availability, amount,
direction and/or restriction of airflow influence the temperatures of these components.

WARNING!

RISK OF FIRE!

A blown fuse is an indication of catastrophic failure of circuit component(s). Repair
must be performed by SL Power Electronics Corp. authorized personnel. Fuse F1 must
be replaced with T 2 A 250 V (slow blow), UL Listed and CSA Certified type.

C O N N E C T I O N S

Multi-Output Models

Single Output Models

J1 Pin

AC Input

J2 Pin

DC Output

J2 Pin

Sense

1

Line

1

Output #2 (+)

1

Output (+)

3

Neutral

2

Output #1 (+)

2

Output (+)

CAUTION:

3

Output #1 (+)

3

Output (+)

Do not exceed 5 A

4

Common

4

Common

per contact.

5

Common

5

Common

6

Output #3 (-)

6

Common

Mating Connectors:

Amp P/N 640250-3

Amp P/N 640250-6

Amp P/N 640250-6

Contacts:

Amp P/N 770476-1

Amp P/N 770476-1

Amp P/N 770476-1

SL Power Electronics Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than
authorized agents of SL Power Electronics Corp., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, IEC/EN
safety standards.

41-33897-0001 Rev. H 9/22/06

GLC40 SERIES

INSTALLATION INSTRUCTIONS

Attention, Consult
Accompanying Documents

Alternating Current

Attention, Dangerous Voltages

Earth (Ground)

EXPLANATION OF SYMBOLS

Direct Current

Advertising