SL Power Electronics GLC50 Triple User Manual

SL Power Electronics Equipment

Advertising
background image




SL Power Electronics, Corp..
6050 King Dr. Bldg. A
VENTURA, CA 93003 + 805-486-4565

MODEL NUMBERS: GLC50X -YYYG, where X represents the output voltage selected from the Table below, -YYY
represents Value Added Options not related to Safety and G represents compliance to RoHS. Model may be followed by
suffix –C for chassis & cover option.

R A T I N G S

Input: 100-240 VAC, 1.4 A, 50/60 Hz
Output:

Model

1

Watts

2

Output #1

Output #2

Output #3

GLC50A

50

+5.05VDC 4A

+12VDC 2.5A

-12VDC 0.2A

GLC50B

50

+5.05VDC 4A

+15VDC 2.5A

-15VDC 0.2A

GLC50D

50

+5.05VDC 4A

+24VDC 1.5A

-12VDC 0.2A

GLC50G

50

+3.3VDC 4A

+12VDC 2.5A

-12VDC 0.2A

Notes:
1. Model may be followed by -C for Chassis & Cover option.
2. -C option requires 24 cfm minimum airflow for full rated output power.
3. Maximum operating ambient is 50°C.
4. Maximum Relative Humidity 96%, no condensation.

SAFETY DECLARATION:

SL Power Electronics Corp. (SLPE). declares under our sole responsibility

that all models listed above are in conformity with the applicable requirements of EN60950 following the
provisions of the Low Voltage Directive 2006/95/EC. All models are Certified to be in compliance with the

applicable requirements of EN/IEC/UL 60950-1 1

st

Ed., CSA 22.2 No. 60950-1-03 1

st

Ed. for Pollution Degree 2

environment and Class I TN-S power systems. The outputs of the supplies meet the requirements for SELV and are not an
energy hazard.

The ground terminal must be bonded to Earth in the end application. Using this terminal for the primary system earthing
terminal is not recommended.

CHASSIS AND COVER INSTALLATION: The insulator provided with the chassis and cover must be installed on the J1
side of the enclosure. Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in
the applicable safety standards, must be maintained after installation to preserve the intended safety.

The maximum operating temperatures of certain safety components, as defined in the applicable safety standards, must not be
exceeded after installation to preserve the intended safety. The output power, ambient air temperature and the availability,
amount, direction and/or restriction of airflow influence the temperatures of these components.

WARNING! RISK OF FIRE!

A blown fuse is an indication of catastrophic failure of circuit component(s). Repair must be performed by SLPE authorized
personnel. Fuse F1 must be replaced with T 2A 250V (slow blow), UL Listed and CSA Certified type.

C O N N E C T I O N S

J1 Pin

AC Input

J2 Pin

DC Output

1

Line

1

Output #2 (+)

3

Neutral

2

Output #1 (+)

3

Output #1 (+)

4

Common

5

Common

6

Output #3 (-)

SLPE will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized agents of
SLPE, or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, IEC and/or EN safety standards.

41-34472-0001 Rev. E 03/26/08

INSTALLATION INSTRUCTIONS

GLC50 MULTI OUTPUT SERIES

MATING CONNECTORS

J1 Amp Housing 640250-3 Contact 770522
J2 Amp Housing 640250-6 Contact 770522

Advertising
This manual is related to the following products: