SL Power Electronics GLM50 Triple O/P User Manual

SL Power Electronics Equipment

Advertising
background image




SL Power Electronics, Corp..
6050 King Dr. Bldg. A
VENTURA, CA 93003 + 805-486-4565

MODEL NUMBERS: GLM50X -YYYG, where X represents the output voltage selected from the Table below, -YYY
represents Value Added Options not related to Safety and G represents compliance to RoHS. Model may be followed by
suffix –C for chassis & cover option.

R A T I N G S

Input: 100-240 VAC, 1.4 A, 50/60 Hz
Output:

Model

1

Watts

2

Output #1

Output #2

Output #3

GLM50A

50

+5.05VDC 4A

+12VDC 2.5A

-12VDC 0.2A

GLM50B

50

+5.05VDC 4A

+15VDC 2.5A

-15VDC 0.2A

GLM50D

50

+5.05VDC 4A

+24VDC 1.5A

-12VDC 0.2A

GLM50G

50

+3.3VDC 4A

+12VDC 2.5A

-12VDC 0.2A

Notes:
1. Model may be followed by -C for Chassis & Cover option.
2. -C option requires 24 cfm minimum airflow for full rated output power.
3. Maximum operating ambient is 50°C.
4. Maximum Relative Humidity 96%, no condensation.

CERTIFICATION: All models are Certified to be in compliance with the applicable requirements of
UL/CSA/EN/IEC 60601-1.

CLASSIFICATION:

(5.1) Protection against electric shock = Class I

(In accordance with sub-

(5.2) Degree of protection against electric shock = Signal output or intermediate

clause 5 of IEC 601-1)

(5.3) Protection against harmful ingress of water = Ordinary (no protection)

(5.5) Have not been evaluated for use in the presence of a flammable anaesthetic

mixture with air, oxygen, or nitrous oxide. This evaluation is to be made
on the end equipment by the OEM.

(5.6) Mode of operation = Continuous

SAFETY DECLARATION:

SL Power Electronics Corp (SLPE) declares under our sole

responsibility that all models listed above are in conformity with the applicable requirements of
EN60950 following the provisions of the Low Voltage Directive 2006/95/EC.

GROUNDING: The Protective Earth (ground) terminal must be bonded to Protective

Earth in the host equipment. Using the Protective Earth terminal on the supply for grounding the host
equipment is not recommended. A separate dedicated grounding point should be used.

OUTPUTS: Output common should be connected to Protective Earth in the end application. The
output is intended for Protectively Earthed Signal Output and Intermediate Circuits only. The output is
not acceptable for patient connection without additional isolation. The DC output is SELV under normal
and single fault conditions.

OVERVOLTAGE PROTECTION: The output is monitored for an overvoltage condition. In some
applications where an overvoltage condition could result in a hazard as defined in applicable safety
standards, redundant or additional overvoltage protection may be required. Consult factory for details.

41-34649-0001 Rev. F 3/28/08

Page 1 of 2

INSTALLATION INSTRUCTIONS

GLM50 MULTI OUTPUT SERIES