SL Power Electronics GLM75 Multiple Output User Manual

Page 2

Advertising
background image

Attention, Consult
Accompanying Documents

Alternating Current

Attention, Dangerous Voltages

Earth (Ground)

EXPLANATION OF SYMBOLS

Direct Current

OVERVOLTAGE PROTECTION: Only output #1 is monitored for an overvoltage condition. The trip-
point for a 5 volt output is 5.6 to 6.8 volts. In some applications where an overvoltage condition could
result in a hazard as defined in applicable safety standards, redundant or additional overvoltage protection
may be required. Consult factory for details.

CAUTION: When performing Dielectric Strength Tests, catastrophic failure of the unit may result if a
Dielectric Strength test voltage greater than 1800 V ac is applied between primary and secondary circuits.
The components providing isolation from primary to secondary cannot be tested while installed in the
power supply without overstressing basic (primary to ground) insulation. All isolating components are
individually 100 % tested at 4800 V ac prior to installation.

ISOLATION: The creepage distance between primary and ground is 4 mm minimum; between primary
and secondary circuits is 8 mm minimum. Secondary to ground creepage is not defined or controlled. The
output common is bypassed to ground using a 0.01 µF 1 kV capacitor. The required creepage and clearance
distances from primary circuits to ground and secondary circuits must be maintained after installation to
preserve the intended safety.

TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the
applicable safety standards, must not be exceeded after installation to preserve the intended safety. The
output power, ambient air temperature and the availability, amount, direction and/or restriction of airflow
influence the temperatures of these components.

OVERCURRENT PROTECTION: The internal fuse is located in the phase lead only. UL 2601-1, CSA
22.2 No. 601.1, EN 60601-1, and IEC 60601-1 requires that both supply leads (phase and neutral) be
protected against overcurrent except for permanently installed equipment. Complete overcurrent protection
must be provided in the end equipment. Fuse ratings must not exceed that specified for the internal fuse,
must be acceptable for the country in which the end equipment is to be installed.

WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit
component(s). Repair must be performed by Condor authorized personnel. Refer to fuse marking on the
supply for rating.

WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, printed wiring
traces and heatsinks.

C O N N E C T I O N S

MATING CONNECTORS

J1 Amp Housing 640250-5 Pin 770522-1

CAUTION

J2 Amp Housing 1-640250-3 Pin 770522-1

Do not exceed 5 A per contact.



Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are
carried out by other than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation
instructions and the applicable UL, CSA, and EN/IEC safety standards.

41-34310-0001 Rev. J

Page 2 of 2

Multi-Output Models

J1 Pin

AC Input

J2 Pin

DC Output

J2 Pin

DC Output

1

Ground

1

Output #1 +

8

Output #2 +

3

Neutral

2

Output #1 +

9

Output #2 +

5

Line

3

Output #1 +

10

Power Fail

4

Common

11

Output #3 -

5

Common

12

Output #4 -

6

Common

13

Output #4 +

7

Common

Advertising