MODEL NUMBERS: Model GLM75–X where X represents the output voltage, which may be any
number from 5 thru 28. Models may be followed by suffix –L for chassis bracket.

RATINGS:

Input:

100-240 V ac, 3.0 A, 50/60 Hz

Output:

5 thru 28 V, 20 thru 4 A

70 W maximum for output voltages from 5 thru 11 V with convection cooling

75 W maximum for output voltages from 12 thru 28 V with convection cooling

100 W maximum for output voltages from 5 thru 11 V with 26 CFM forced air cooling

110 W maximum for output voltages from 12 thru 28 V with 26 CFM forced air cooling

Notes:
1. Maximum operating ambient temperature is 50 °C.
2. Maximum Relative Humidity 96 %, no condensation.
3. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of

power.

CERTIFICATION: All models are Certified to be in compliance with the applicable requirements of
UL 2601-1 2

nd

Edition, CSA 22.2 No. 601.1-M90, EN 60601-1: 1990, and IEC 60601-1 (1988).

CLASSIFICATION:

(5.1) Protection against electric shock = Class I

(In accordance with (5.2) Degree of protection against electric shock = Signal output or intermediate

sub-clause 5

(5.3) Protection against harmful ingress of water = Ordinary (no protection)

of IEC 60601-1)

(5.5) Have not been evaluated for use in the presence of a flammable anaesthetic
mixture with air, oxygen, or nitrous oxide. This evaluation is to be made on the
end equipment by the OEM.

(5.6) Mode of operation = Continuous

SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole
responsibility that all models listed above are in conformity with the applicable requirements
of EN 60950 following the provisions of the Low Voltage Directive 73/23/EEC.

GROUNDING: The Earth (ground) terminal J1, pin 1, must be bonded to Protective Earth in the end
application to preserve the intended safety. Using the Earth terminal on the supply for grounding the end
product’s protective earthing terminal is not recommended. A separate dedicated protective earthing
point should be used.

OUTPUT: Output common should be connected to Protective Earth in the end application. The output
is intended for Protectively Earthed Signal Output and Intermediate Circuits only. The output is not
acceptable for patient connection without additional isolation. The DC output is SELV under normal
and single fault conditions.

OVERVOLTAGE PROTECTION: The output is monitored for an overvoltage condition. In some
applications where an overvoltage condition could result in a hazard as defined in applicable safety
standards, redundant or additional overvoltage protection may be required. Consult factory for details.

41-34470-0001 Rev. F