OVERVOLTAGE PROTECTION: The output is monitored for an overvoltage condition. In some
applications where an overvoltage condition could result in a hazard as defined in applicable safety
standards, redundant or additional overvoltage protection may be required. Consult factory for details.

DIELECTRIC STRENGTH TEST CAUTION: When performing Dielectric Strength Tests,
catastrophic failure of the unit may result if a Dielectric Strength test voltage greater than 1800 Vac is
applied between primary and secondary circuits. The components providing isolation from primary to
secondary cannot be tested while installed in the power supply without overstressing basic (primary to
ground) insulation. All isolating components are individually 100% tested at 4800 Vac prior to
installation.

MAINTAINING ISOLATION: The creepage distance between primary and ground is 4 mm minimum;
between primary and secondary circuits is 8 mm minimum. Secondary to ground creepage is not defined
or controlled. The output is bypassed to ground with a capacitor. The required creepage and clearance
distances from primary circuits to ground and secondary circuits must be maintained after installation to
preserve the intended safety.

TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in
the applicable safety standards, must not be exceeded after installation to preserve the intended safety.
The output power, ambient air temperature and the availability, amount, direction and/or restriction of
airflow influence the temperatures of these components.

CONNECTIONS







Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other
than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA,
and EN/IEC safety standards.

41-35163-0001 Rev. A 9/24/01

Page 2 of 2

J1 AC Input

J2

Function

1 Line

1,2,8,9

+24 V dc Output

2 Neutral

3,4,10,11

Common

3 Earth

5

N/C

6

AC Good

7

AC Good Return

12

N/C

13

DC Good

14

DC Good Return

MATING CONNECTORS

J1: Molex P/N 44441-2003 (Housing)

Molex P/N 43375-0001 (Pins)

J2: Molex P/N 39-01-2145 (Housing)

Molex P/N 5556/44476 (Pins)

CAUTION: Do not exceed 7 A per pin on connector J2

Attention, Consult
Accompanying Documents

Alternating Current

Attention, Dangerous Voltages

Earth (Ground)

EXPLANATION OF SYMBOLS