Installation instructions – SL Power Electronics GPMP600 User Manual

Page 2

Advertising
background image

WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, printed wiring traces and heatsinks.


AIRFLOW/COOLING: The GPHP600/700 series is designed with two integral fans that are rated 54 cfm total.

VOLTAGE ADJUSTMENT: Factory set to specified voltage. User accessible pot allows adjustment over a range of ±5%
of nominal voltage. The potentiometer is located on the A2 PWB located behind and above J1.


Connector: ERNI Type H15 P/N 123767 or AVX ELCO 108456015001169 DIN 41612 Style H15

AC INPUT

STATUS and CONTROL

Line

Z32

AC Power Fail

D22

Neutral

D30

DC Power Good

Z20

Reference to Common

Ground

Z28, D26

Inhibit

Z24

DC OUTPUT

Z12, D14, Z16, D18

Main Output

Output #1

Z4, D6, Z8, D10

Rtn (Common)

Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes,
modifications or repairs are carried out by other than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply
is not in accordance with these installation instructions and the applicable UL, CSA, and EN/IEC safety standards.

41-35343-0002A 8/5/04

INSTALLATION INSTRUCTIONS

GPMP600/700 SERIES (Contd.)

Attention, Consult
Accompanying Documents

Alternating Current

Attention, Dangerous Voltages

Earth (Ground)

EXPLANATION OF SYMBOLS

Direct Current

VOLTAGE ADJUSTMENT: Factory set to specified voltage. User
accessible pot allows adjustment over a range of ±5% of nominal voltage.
The potentiometer is located on the A2 PWB located behind and above J1.

C O N N E C T I O N S