SL Power Electronics Linear Instructions E to G Case User Manual

International + series installation instructions

Advertising
background image

SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com

RATINGS:

Input:

100/120/215/230-240 V ac, 50/60 Hz, Refer to chassis marking for input current ratings.

Output:

Model

Output Ratings at 25°C Ambient With Airflow Specified - See Notes

Airflow

Level

Notes

CP197-A+

5 V 50 A (derate to 44 A at 50 °C)

35 cfm

L5

2,4,6

F5-25/OVP-A+

5 V 25 A

14 cfm

L3M1

2,3

F15-15-A+

12 V 16 A or 15 V 15 A

35 cfm

L5

2,3,5

F24-12-A+

24 V 12 A (derate to 10 A at 50 °C) or 28 V 10 A (derate to 8.6 A at 50 °C)

35 cfm

L5

2,4,6

F48-6-A+

48 V 6 A (derate to 5 A at 50 °C)

35 cfm

L1

2,4,7

G5-35/OVP-A+

5 V 35 A

35 cfm

L5

2,3,5

HDBB105W-A+

5 V 12 A; +12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or –15 V 1.5 A or –5 V 0.7 A

26 cfm

L3M1

2,3

HDCC150W-A+

5 V 12 A; +12 V 3.4 A or +15 V 3 A; -12 V 3.4 A or –15 V 3 A or –5 V 1.5 A

35 cfm

L3M1

2,3

HDD15-5-A+

±12 V 5 A or ±15 V 5 A

14 cfm

L3M1

2,3

HE12-10.2-A+

12 V 10.2 A

14 cfm

L3M1

2,3

HE15-9-A+

15 V 9 A

14 cfm

L3M1

2,3

HE2-18-A+

2 V 18 A

14 cfm

L3M1

2,3

HE24-7.2-A+

24 V 7.2 A

14 cfm

L3M1

2,3

HE28-6-A+

28 V 6 A

14 cfm

L3M1

2,3

HE48-4-A+

48 V 4 A

14 cfm

L1

2,3,8

HE5-18/OVP-A+ 5 V 18 A

14 cfm

L3M1

2,3

Notes:

1.

Models may be followed by suffix G to indicate compliance to RoHS.

2

Derate output current ratings 10 % for operation at 50 Hz.

3.

No derating required for operation at 50 °C ambient unless specified otherwise above.

4.

For operation at >25 °C to 50 °C, derate output linearly to value shown in table.

5.

Output capable of exceeding 240 VA when overloaded.

6.

Output rating exceeds 240 VA.

7.

Output exceeds 240 VA and may exceed 60 V dc as a result of a component failure.

8.

Output may exceed 60 V dc under certain conditions.

9.

Maximum Relative Humidity 96 %, no condensation.

10.

Storage: -40 °C to +80 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.

SAFETY DECLARATION:

SL Power Electronics Corp. declares under our sole responsibility that all

models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions
of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable
requirements of UL 1950, CSA 22.2 No. 234 (see table for level), and EN 60950-1 for Pollution Degree 2

environment and Class I TN-S power systems. The output of some models poses an energy hazard or do not meet the
requirements for SELV. To identify these models, refer to the notes for the table above.

GROUNDING: Protection Class I requires that the chassis be bonded to Protective Earth in the end application.

SPACINGS:

Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the

applicable safety standards, must be maintained after installation to preserve the intended safety.

TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the applicable safety
standards, must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature
and the availability, amount, direction and/or restriction of airflow influence the temperatures of these components.

WARNING!

RISK OF FIRE!

All models require

external fusing to maintain the intended safety. Refer to
marking on chassis for maximum fuse ratings.

AC INPUT HOOKUP

INSTRUCTIONS

41-33496-0001 Rev. G 09/12/06 SHT 1 OF 2

INTERNATIONAL + SERIES

INSTALLATION INSTRUCTIONS

3

5
4

100 VAC

3

5
4

120 VAC

3

5
4

215 VAC

1

2

1

2

1

2

3

5
4

230-240

VAC

1

2

Advertising