Check to make certain that the “L” dimension shown on the flushometer

package is correct for your application. Determine the “L” dimension for

your application by using the following formula:

“L” dimension = Wall Thickness (To Nearest Whole Inch) + 2-3/4”

Prior to installing a concealed flushometer, perform the following functions

as illustrated in the Rough-in Diagrams on Pages 2 and 3.

• Bore a 1-1/2” (38 mm) hole in wall for Actuator.
• Bore a 2” (51 mm) [1” (25 mm) for Model 197 only] hole in wall for

piping, if required.

• Install closet or urinal fixture.
• Install 1-1/2” (38 mm) drain line (NOT supplied by Sloan).
• Install water supply line. Note: Concealed valves are supplied with double

handle opening to allow for installation of Control Stop on either the left
or right side of the valve (refer to illustration in Step 4).

IMPORTANT:

INSTALL ALL PLUMBING IN ACCORDANCE WITH

APPLICABLE CODES AND REGULATIONS.

• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN

ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.

• FLUSH ALL WATER LINES PRIOR TO MAKING

CONNECTIONS.

Sloan’s flushometers are designed to operate with 10 to 100 psi (69 to 689

kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED

TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE

SELECTED. Consult fixture manufacturer for minimum pressure

requirements.
Most Low Consumption water closets (1.6 gpf/6.0 Lpf) require a minimum

flowing pressure of 25 psi (172 kPa).

Code No. 0816170

Rev. 3 (04/14)

INSTALLATION INSTRUCTIONS FOR

CONCEALED CLOSET AND URINAL FLUSHOMETERS

LIMITED WARRANTY

Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and
workmanship for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase.
During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under
normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims
will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from
Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN

VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

Concealed Closet Flushometer —

1-1/2” Exposed Back Spud

MODEL 140

MODEL 154

Concealed Closet Flushometer —

1-1/2” Exposed Top Spud

MODEL 142

MODEL 153

Concealed Closet Flushometer —

1-1/2” Back Spud

MODEL 143

MODEL 144

MODEL 150

MODEL 152

Concealed Urinal Flushometer —

Back Spud

MODEL 190

MODEL 195

Concealed Urinal Flushometer —

Exposed Top Spud

MODEL 192

MODEL 197

Model 140

Model 195

PRIOR TO INSTALLATION

TOOLS REQUIRED FOR INSTALLATION

• Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench
• Drill to bore 1½” (38 mm) and/or 2” (51 mm) hole(s) in wall (see rough-in)

WITH THE EXCEPTION OF CONTROL

STOP INLET, DO NOT USE PIPE THREAD

SEALANT OR PLUMBING GREASE ON VALVE

COMPONENTS OR COUPLINGS!