3

INSTALLATION INSTRUCTIONS

Step 1 — Pedestal Mounting

Measure and mark the centerline of the Washfountain on the wall and floor.

Note: For off-the-floor units, mark a level horizontal line at 36½” above the finished floor

for a rim height of 34”.

Place Back Panel against wall and align the three middle mounting holes with

the centerline marked on wall. Back Panel must be level and plumb against the

wall so that water in Basin will drain correctly once assembly is completed.

Note: For off-the-floor units, align top of pedestal with the horizontal line.

Drill holes in wall at all mounting hole locations on the back panel.
Secure Pedestal to wall using bolts, washers and wall anchors that are suitable

for your specific type of wall: drywall, concrete, metal studs, wood studs, etc.

(Wall anchors supplied by installer.)
Once Pedestal is secured to the wall, locate the 2 (two) Rubber Grommets

(supplied) and insert them into the 2 (two) 1¾” diameter holes located on top

of Pedestal.

PRIOR TO INSTALLATION

Prior to installing the Sloan Optima EWF-40000 Series Lavatory System, install the

items listed below. Also, refer to the appropriate rough-in diagram on Page 2.
• Plug-IIn TTransformer — Install electrical receptacle(s) for plug-in transformer(s)

— 120 VAC, 2 amp service for each ETF-233 (24 VAC, 35 VA) plug-in transformer

used.

• Hot and cold water supply lines or tempered water supply line
• Drain line

Important:

ADEQUATE STRUCTURAL SUPPORT IN OR BEHIND THE WALL IS REQUIRED.

REFER TO THE APPROPRIATE ROUGH-IN DIAGRAM ON PAGE 2 FOR DRY WEIGHT

OF SINK. STRUCTURAL SUPPORT MUST HAVE A MINIMUM PULLOUT RATING OF

1000 POUNDS (450 Kg).

ALL ELECTRICAL WIRING SHOULD BE INSTALLED IN ACCORDANCE WITH

NATIONAL/LOCAL CODES AND REGULATIONS.

ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE

CODES AND REGULATIONS.

A 24 VAC STEP-DOWN TRANSFORMER MUST BE USED FOR HARDWIRE

APPLICATIONS.

DO NOT PLUG TRANSFORMER INTO POWER SOURCE (RECEPTACLE) UNTIL ALL

WIRING IS COMPLETED. PERMANENT DAMAGE TO THE TRANSFORMER AND

CIRCUIT CONTROL MODULE WILL RESULT IF 24 VAC WIRES TOUCH

EACH OTHER OR SHORT WHEN POWER SUPPLY IS ACTIVE.

BEFORE CONNECTING FLEX HOSES TO SUPPLY STOPS, FLUSH ALL

WATER LINES UNTIL WATER IS CLEAR.

TOOLS REQUIRED FOR INSTALLATION

• Electric drill for drilling anchor holes.
• Socket or open end wrench for installing anchoring fasteners.
• Open end wrench for connecting water lines.
• Pipe wrench for installing drain line.

SINK LOCATION

Determine the appropriate wall location for the Lavatory System. Consider

that hot and cold water supply lines, a drain line, and an electrical source

(receptacle) will be required. Compare the physical dimensions of the

Lavatory System to the space available for the installation. If wall is not

load bearing, a carrier may be required behind the wall. Refer to the

appropriate Rough-in diagram on Page 2 for Lavatory System dimensions.
Prior to Lavatory System installation, electric wiring, plumbing supply and

drain must be installed.

A

Step 2 — Strainer Installation

Insert Drain Spud into Basin using plumbers putty (supplied by installer).
From beneath Basin, install the Washer and Locknut onto the Drain Spud and

secure Locknut against Basin.
Install Strainer using the 2 (two) #10-24 x ½” flat Phillips-head screws

supplied.

STRAINER

DRAIN SPUD

LOCKNUT

WASHER

BASIN

RUBBER GROMMETS

PEDESTAL

B

C
D

E

A
B

C

Advertising