2.4. tIPs and reCommendatIons for InstallatIon

2.4.1. questions about the sonesse Ultra 50 rs485?

2.3. CommIssIonIng

To set the motor, use the RS485 SETTING

TOOL ref:9017142A

Connect the RS485 SETTING TOOL to the motor

switch on and follow the instruction on the RS485

SETTING TOOL (Pxx).

2) Data cable RJ9/RJ9

* Power out specification : 7.5V /30 mA max.

1: + RS485

2: - RS485

3: Power out *

4: GND

1

2

3

4

5

6

7

8

4

3

2

1

1: + RS485

2: - RS485

3: Power out *

4: GND

1

2

3

4

5

6

7

8

4

3

2

1

RJ9

RJ9

Observations

Possible causes

Solutions

The motorised

product does not

operate.

The wiring is incorrect.

Check the wiring and modify it if

necessary.

The motorisation is in thermal

protection.

Wait until the motor cools down.

An incorrect Data cable has been

used.

Check the Data cable

The motorised

product is noisy:

The drive wheel and the crown

are not suitable for the tube.

Replace the drive wheel and the crown

The motorised product is com-

pressed between the brackets

Increase the play between the brackets

The tube contains swarf and

screws.

Clean the roller tube.

The motorised product

stop to soon or to late.

The end-limits of the motorised product

drift.

Readjust the end-limits