Step four operation – SOMFY SUNIS INDOOR WIREFREE RTS SUN SENSOR User Manual

Page 3

Advertising
background image

STEP FOUR OPERATION

DEMONSTRATION MODE

The Sunis WireFree RTS Light Sensor cans be operated in either
Demonstration Mode (temporary) or Standard (default) mode.

1. Press and hold MODE BUTTON until LED indicator blinks (color red)
LED will continue to blink for approx. 30 seconds then extinguish.
(See Figure 5)

2. If necessary, adjust sun sensitivity (threshold) setting (refer to STEP 3. [4 & 5] )
LED will blink during this mode. Should LED indicator extinguish prior to final setting, simply press the

mode button momentarily to reactivate blinking LED indicator.

3. Sunis RTS light sensor will send a "DOWN" command to the RTS receiver or motor after 5 seconds of sensing light
within the set threshold.

4. Sunis RTS light sensor will send a "UP" command to the RTS receiver or motor IMMEDIATELY after sensing light that

HAS NOT reached (or below) the set threshold.

Note:
1. Sunis light sensor will automatically default to standard operating mode after 3 minutes.

2. Rotating the Sun Sensitivity Selector to a FULL COUNTER CLOCKWISE (-) position will simulate sun

if no sun is present. It is not recommended to leave the selector (Threshold setting) in this position.

*

Standard operating mode (default) employs output response time delays.

1. Refer to STEP 3. [1-5] (Setting the Light (Sun) Sensitivity Threshold)

2. Sunis RTS light sensor will send a "DOWN" command to the RTS receiver or motor after 5 Minutes of sensing light

within the set threshold.

3. Sunis RTS light sensor will send a "UP" command to the RTS receiver or motor after 30 Minutes of sensing light that

HAS NOT reached (or below) the set threshold.

GREEN LED: INDICATES SUN (Light) WITHIN THRESHOLD SETTING
RED LED: INDICATES SUN (Light) BELOW THRESHOLD SETTING

Demonstration mode reduces the standard operating time delays,
permitting almost instantaneous operating/output response from the

Sunis light sensor. This mode facilitates initial light sensitivity (threshold)

settings and quickly demonstrates the operation of the motorized end product.

STANDARD OPERATING MODE

Note: LED indicator light will remain illuminated for approx. 15 seconds. To confirm

present light level, momentarily press the mode button to illuminate the LED indicator light.

TI N B Y

Sunis WireFree RTS Light Sensor Programming/Operating/Installation Instructions

On/Off
Selector Switch

Control
Setting Panel

Mode Button

*

Sun

Sensitivity
Selector

LED
Indicator

FIGURE 5

P.3 Rev2.

Note: The Sunis WireFree RTS light sensor is capable of providing control in accordance to light level conditions only.
Once a command is sent, the Sunis will not send another command until there is a change in light condition.

Advertising