Rack mounting the model 45dc, Ethernet connection – Studio Technologies 45DC User Manual

Page 10

Advertising
background image

Issue 1, January 2015

Model 45DC User Guide

Page 10

Studio Technologies, Inc.

Rack Mounting the Model

45DC

For permanent or mobile applications it

might be desirable to mount one or two

Model 45DC units into one space (1U) of

a 19-inch rack enclosure. Two rack-mount

front panels, purchased separately, are

available from Studio Technologies. The

following provides details on how to install

and use the panels.
To attach a Model 45DC unit to the single-

unit rack-mount panel, begin the process

by using a 5/64-inch hex wrench to remove

the four 4-40 thread hex-head machine

screws that hold the standard front panel

to the chassis. Note that the screws might

be quite tightly affixed. Ensure that a good-

quality hex wrench is used and press and

hold it firmly while turning counterclock-

wise. Unless this recommendation is fol-

lowed the wrench can “cam out” and the

head could be “stripped.”
Using the screws that were just removed,

attach the rack-adapter front panel to the

Model 45DC’s chassis. To prevent damage

care is required when aligning the front

panel with the LEDs and auto null push-

button switch that protrude through both

the Model 45DC’s chassis and front panel.

Tighten the four screws only after a careful

inspection ensures that the switch and all

28 of the LEDs protrude through the front

panel without interference. To allow vertical

clearance in the associated rack, remove

the four “bump on” protectors from the

bottom of the chassis. They are removed

by using the fingers to rotate them coun-

ter-clockwise; no tool is required. Carefully

protect and store the standard front panel,

along with the “bump on” protectors, for

possible later use.

Mounting a Model 45DC to a dual-unit

rack-mount panel follows the same proce-

dure but will apply to two units. Store both

of the removed standard front panels and

the eight “bump on” protectors for pos-

sible later use. Note that on the rack-panels

graphics the unit on the left is designated

as A while the unit on the right is desig-

nated as B. This is provided so that each

can be easily identified during installation,

troubleshooting, and operation.
Once the desired one or two Model 45DC

units have been installed in a rack-mount

front panel, the assembly can be mount-

ed into the designated equipment rack.

One space (“1U” or 1.75 vertical inches)

in a standard 19-inch equipment rack

is required. Secure the front panel into

the equipment rack using two mounting

screws per side.

Ethernet Connection

An Ethernet connection that supports

100BASE-TX (100 Mb/s over twisted-pair) is

required for the Model 45DC’s Dante Au-

dio-over-Ethernet connectivity. A 10BASE-T

connection is not sufficient for Model 45DC

operation. A 1000BASE-T (“GigE”) connec-

tion is not supported unless it can automat-

ically “fall back” to 100BASE-TX operation.

An Ethernet connection that supports

Power-over-Ethernet (PoE) is preferred as it

will provide operating power for the Model

45DC. To support PoE switch (PSE) power

management the Model 45DC will enumer-

ate itself as a PoE class 3 device. If PoE is

not available an external 12 volt DC power

source can be connected. This will be dis-

cussed in the next section of this guide.
The 100BASE-TX Ethernet connection is

made by way of a Neutrik etherCON pro-

tected RJ45 connector that is located on