Model 45DR User Guide

Issue 2, January 2015

Studio Technologies, Inc.

Page 21

7. At this time the Model 45DR is function-

ing with the newly-loaded application

firmware and the USB flash drive can

be removed. But to be conservative,

remove power first and then remove

the USB flash drive.

8. Apply power to the Model 45DR and

“read” the application firmware version

number by observing the channel 2

level meters. Ensure that this is the de-

sired version and that it’s different from

that noted in step 2.

Note that upon power being applied to the

Model 45DR if the USB flash drive doesn’t

have the correct file (

M45DR.bin) in the

root folder no harm will occur. Upon power

up the USB LED will flash on and off

rapidly for a few seconds to indicate this

condition and then normal operation using

the unit’s existing application firmware will

begin.

Ultimo Firmware Update

As previously discussed in this guide, the

Model 45DR implements Dante connectiv-

ity using the Ultimo integrated circuit from

Audinate. This 2-input/2-output device can

be updated by way of the Model 45DR’s

Ethernet connection. The latest Dante

firmware file is available on the Studio

Technologies website. The Dante Firm-

ware Update Manager application is used

to install the firmware. This program is

also available for download on the Studio

Technologies website.