1500 VRF User’s Manual Rev -

Overview and Set Up


The 1500 VRF (P/N 13563) is a complete carbon control unit with a touch screen
operator interface.

There are three indicators on the front of the enclosure. When the unit is powered on,
the white light labeled “Control Power On” will be lit. During a burnoff, the green light
above the burnoff air flow meter will be lit. The red switch labeled “Process Alarm”
allows the operator to silence the unit if it is alarming.

For information on wiring the probe mV and probe thermocouple to the unit, please
reference the VRF 1500 electrical drawings in this manual.

Connect the ports on the side of the electrical enclosure to the probe using silicone
tubing. Connect tubing from the fitting on the side of the electrical enclosure marked
“Reference Air” to the “Ref. Air” port on the probe. A connection should also be made
between the “Burnoff Air” fitting and the “B.O.” fitting on the probe. Please see the
1500 VRF plumbing connections diagram within this manual. There is a barb fitting on
the stainless steel well on the heated probe. This is the vent, which needs to be routed
to an appropriately safe location.

The flow of the reference air and burnoff air can be adjusted using the corresponding
flow meters on the front of the unit.

For information on the touch screen operator interface, please reference the

9120 With

Touch Screen Interface User’s Manual.

For information on the probe, please reference

the

Gold Probe Instruction Manual.