8. TECHNICAL

CHARACTERISTICS

8.1. Power supply

CR-2450 lithium battery


Nominal voltage:

3V

Capacity: 560

mAh

Power consumption:

8 µA

8.2. Totalizer Counter

N. of digits:

7

Size of the digit:

8 mm

Reset:

Cannot be reset

8.3. Partial Counter

N. of digits:

5

Size of the digit:

6 mm


Reset:

By means of push button or magnet.

8.4. General characteristics

Ingress protection:

IP65

Ambient temperature range:

0 … +60 ºC

8.5. Input terminals for CIP II for local mounting

Terminal n. COVOL Turbine
1

Common

Ground

2

Live

Live

3

Live

Input characteristics

8.5.1. COVOL

This input is designed for a potential free contact between terminals 1 & 2 of the
connector. Terminal 1 is connected to the common of the instrument. This input
has a 1 MΩ pull-up resistor connected to terminal 1 and to the 3,3 V power supply.
The input has a hysteresis with the switching points situated at about 1 V & 2,1 V.
If an open collector transistor is to be used as the switching element instead of a
COVOL, then the aforementioned parameters must be taken into account.

Due to the presence of a filter to avoid the effects of contact bounce, the maximum
pulse frequency for the COVOL input is 300 Hz.
The minimum input frequency is 0.06 Hz

1 M