WORKING


The APTM44 needs no adjusting to adapt to the pick-up or control instrument.


In the event that there are pulse outputs with no flow in the turbine, what is most probable is that

the cables to the pick-up are too long or that they are too near mains cables.

7

TECHNICAL CHARACTERISTICS


8.1

Environment


The plastic case has protection as per IP 40 and the terminals as per IP 20.


The working temperature limits are 0 to 50

o

C


8.3

Mains supply

The standard mains voltage is 220 Vac 50/60 Hz. AC Mains voltages of 240 V, 110 V y

24 V 50/60 Hz. and 24 Vdc supply voltage are available on order.

The power consumption is less than 1 W.


The instrument is not supplied with a mains filter and in the exceptional cases that, due to high

levels of mains interference, a mains filter is needed, this must be installed externally. Due to the low
power consumption, almost any small mains filter will be adequate.

8.5

Pulse Output


The output pulse has a pulse width of 1 ms.

The TTL outputs are directly from a CMOS integrated circuit and have a load current of 1 mA

maximum.


8.7

Pulse Input



The input is intended for an inductive pick-up coil.


The maximum input frequency is about 1500 Hz.