Thermo Technologies Thermo Alarm User Manual

Page 3

Advertising
background image

Thermo Technologies

August 2002

switch. The large amber LED will blink if the power is connected

correctly and the temperature of monitored room is outside the range.
A small green light comes on showing operation mode of the unit.

Wiring the Alarm

While the large amber LED blinks, the internal relay is on (Black and
White wires). This contact is dry and potential free. It is designed to
give a signal to alarm devices such as auto-dialer or a Piezo
Siren/Alarm.

Calibrations

ThermoAlarm is delivered in Fresh Produce Mode and calibrated at
the factory as follows:

Frozen Food

–20 F to +10 F

Fresh Food

+33 F to +45 F