background image

1) Description of the control unit : 7

7

7

7

7

and

8

8

8

8

8

➊ ➔

/ I /

switch (stop/0). ➋ ➔ Temperature adjustment control knob. V1 ➔ Heating indicator light

2) Fixing the comfort temperature

The comfort temperature is the temperature that you would like while the room is occupied.
a) Put the ➊ switch to

(marche/I).

b) Mechanical : set the ➋ control knob to between 4 and 5.

Electronical : set the ➋ control knob on 5, the heating indicator V1 comes on if the room temperature is below the
required temperature.

c) Wait a few hours for the temperature to stabilise.
d) If the setting is satisfactory (if necessary use a thermometer to check), mark the position for future use.
e) If the setting is not satisfactory, adjust it and start again from point c).

3) Fixing the Eco temperature : (electronic model)

This is the required temperature during periods when the room is unoccupied. It is recommended that this mode should
be used if the room is unoccupied for more than 2 hours.
a) Set the cursor ➊ switch knob to .
b) Adjust the control knob ➋ between 3 and 4, the heating light V1 comes on, if the ambient temperature is lower than
the instruction of desired Eco temperature.
c) Wait a few hours until the temperature stabilizes.
d) If the setting is satisfactory (if necessary use a thermometer to check), mark the position.
If the setting is not satisfactory, adjust it and start again from point c.

4) Frost-Free mode

This mode is used to keep the temperature at approximately 7°C in the room when you are absent from the house for
a prolonged period (i.e. more than 24 hours).
a) Leave the ➊ switch on I , set the ➋ control knob to

(mecanical model).

b) Set the ➊ switch on

(electronic model).

5) The heating indicator : V1 (electronic model)

This light comes on when the heating element is working. It may flash when the temperature has stabilised.

6) Locking the controls : 9

9

9

9

9

and

It is possible to lock or limit use of the ➋ control knob and lock the ➊ switch to prevent unauthorised manipulation of
the panel heater (children, etc.).
a) Unhook the panel heater from its wall mounting.
b) Remove the slugs P on the back of the thermostat from their mountings.
c) Select position B to lock the control knob or position L to limit the amount it can be turned. Position M blocks the switch
for Electronic Model.

7) Using the pilote wire

The product with pilote wire can receive the following signals from a master unit :

- comfort (temperature of

control knob)

- eco (comfort temperature -3°C to -4°C)
- frost free (approximately 7°C)
- off.

Put the switch (1) to the programming mode (clock symbol).
The product must be connected through the pilote wire to a programming control or a product equiped with pass
program system in order to use these different modes. You can control several convectors with a single programmer or
a product equiped with pass program system.

Warning :The control unit will consider frost free and off signals in any switch selection.

USING THE PANEL HEATER

- There is no point in setting maximum heating, the room temperature will not rise any quicker.
- When you air the room, disconnect the panel heater by putting the ➊ switch to STOP/0.
- If you leave for several hours, remember to reduce the temperature.

Absence for :

less than 2 hours, do not touch the controls.
2 to 24 hours, lower the ➋ control knob by two graduations.
more than 24 hours or in the summer, put the ➋ control knob to

(mecanical),

put the ➊ switch on

(electronic).

- If you have several units in a room, let them operate simultaneously. This will give you a more uniform temperature
without increasing electricity consumption.