Setting the comfort temperature

This is the temperature desired when the room is occupied.
1) Set cursor A to position , the indicator V3 lights.
2) Adjust knob C to 5.The heating indicator V1 will illuminate if the temperature is below the desired

temperature.

3) Wait a few hours for the temperature to stabilise.
4) When you are happy with the setting (you may wish to use a thermometer to check), mark the posi-

tion once and for all.
If you are not happy with the setting, re-adjust it and proceed again from point 3).

Setting the Eco temperature

This involves a reduction in degrees compared to the Comfort temperature. We recommend that you
use this mode for periods of absence of more than 2 hours or overnight.
Warning:This reduction applies to the Comfort temperature so it is important to set the Comfort tem-
perature first, before setting the Eco reduction.
1) Set cursor A to position , the indicator V2 lights.
2) Set the knob B to –3.5°, the heating indicator V1 will illuminate if the ambient temperature is less

than the desired Eco temperature.

3) Wait a few hours for the temperature to stabilise.
4) When you are happy with the setting (you may wish to use a thermometer to check), mark the posi-

tion once and for all.
If you are not happy with the setting, re-adjust it and proceed again from point 3).

NB:The measurement is set to –3.5°C in our laboratories. It is possible that the setting for the reduc-
tion is not precisely –3.5°C, depending on your installation’s particular characteristics. In this case, adapt
the setting to obtain the desired reduction.

Standby (Frost Free) Mode

It is the mode to maintain a temperature of approximately 7°C in the room in case of prolonged absence
from the house.

Set cursor A to position .

Description of the control panel

U

SING THE DEVICE

V2

V2

V3

V3

V1

V1

A

B

C

5

-3,5

°

A Mode cursor

B Eco reduction set value adjustment

knob (compared to the Comfort tem-
prature)

C Comfort temperature set value adjust-

ment knob (between 4 and 5 is about
21°C at he heater)

V1 Heating light indicator

V2 Eco mode light

V3 Comfort mode light