Tiffen Lowel Prime LED 200 User Manual

Model 200 instructions

Advertising
background image

Repairs, problems, suggestions
and requests for brochures/catalogs,
instructions and parts lists can be
handled through your Authorized Lowel
Dealer/Distributor or directly through
Lowel. Electrical repairs should
be made only by Lowel or by
a qualified electrician.

Lowel Prime LED equipment is a product of the
ongoing collaborative relationship between
Lowel-Light and Fluotec, Mexico

Lowel Prime™ LED equipment is a pro-
fessional lighting system. Read these
instructions, as well as accessory instruc-
tions and applicable warnings before
operating.

n

Do not leave fixture unattended.
For fixed (stationary) use in studio's, theaters,
and similar locations.

n

Not for household use. Use only for
photographic lighting (video & film imaging).

n

Always unplug unit before
changing fuse.

n

Do not use near standing water.

n

Never bypass plug’s ground pin.

n

Do not interfere with unit’s ventilation.

n

Do not operate unit with
Accessory Barndoors closed.

n

Make sure clamp is tightened at yoke.

n

Always use Safety Cable,
when attaching to overhead pipes or grids.

n

Always use with supplied Lowel
AC Cable.

LED Warnings

n

Avoid looking directly at the LED's
for extended periods of time.

n

LED's take time to reach standard
operating output level, and frequently have
slightly higher output during the first 1/2 hr,
when powered up.

Warnings

Model 200 Instructions

n

Gel Frame

n

Safety Cable

n

Standard C Clamp
yoke hanging mount device

n

Female 5/8" Stand Fitting

n

2 Standard 120v AC power cables with

male Edison connectors (or appropriate interna-
tional CE approved plug). For 120v, use the
unswitched T1-808 AC cable for C-clamp grid, or
pipe hung 'studio' use. Use T1-80 switched AC
Cable for use on stand or boom where access to
fixture power switch may be out of reach.

Each fixture comes with:

On Lighting Rail:

Attach clamp tightly to yoke of fixture, according
to clamp mfrs. instructions. Hang clamp on pipe
or grid and tighten the large screw so that the
clamp and fixture are securely mounted. Do not
loosen bolt attaching clamp to fixture, to position
light. Attach safety cable between the fixture and
the rail for necessary security.

On Stand:

There are 2 options for stand mounting of the fix-
ture, using the 5/8" female stand fitting or using
the optional Male Stud. Choose proper size stand
for fixture. For all models, the Lowel Grand Stand
or larger is preferred, however the following stands
may also be used. Always use sufficient stabilizing
weight on stand base.

Model

Lowel Stand

200

KS or KSA

400

KSA

600

Grand Stand*

*Do not use with top stage extended

Mounting the Fixture

Female 5/8" Stand-fitting:

For use on stand only. Allows mounting the fixture
on 5/8" male stand stud. Make sure the stand
is large enough to support the weight of the
fixture while maintaining good balance at the
desired height. Attach the female stand-fitting
tightly to the yoke and rotate yoke so it is on the
underside of the fixture. Tighten yoke, clamp lock-
ing lever, and place female stand-fitting over
stand, making sure that its locking screw is loos-
ened enough to allow the fitting to completely fit
over the 5/8" stand stud. Tighten knob, making
sure its screw is under the safety cut of the stand
fitting stud. Add additional weight to base of stand
for increased stability.

Male Stud

(Code, FLS-MS):

For use of fixture with Matthews style stands that
have a female cup instead of a male stud. Attach
the optional Male Stud in the same manner as
described above for Female 5/8" Stand Fitting,
again rotating the yoke to the underside of the fix-
ture and tightening yoke clamp. Carefully place
Male Stud into female cup on stand top and tight-
en. Add additional weight to stand base for
increased stability.

Specs & Performance: Daylight & Tungsten Models

Note - Most electrical equipment briefly consumes a higher amount of electrical current during start-
up (ignition). Consult the below chart to confirm that your electrical wiring is sufficient for the fixtures
used. All fuses must be rated at 250VAC. Lowel Prime LED's auto-set from 90-240 VAC.

110V

240V

Model

Fuse

Nominal

Peak

Nominal

Peak

Current

Ignition

Current

Ignition

Current

Current

200

3 A / 250 V

0.714 A

0.97 A

0.403 A

0.61 A

PRIME LED Model 200 Consumes 85 Watts

Fuses & Power Consumption

Problems, repairs & info

90 Oser Avenue, Hauppauge, N.Y. 11788

Call: 800 645-2522 or 631-273-2500

Fax: 631-273-2557

e-mail [email protected]

www.lowel.com

Lowel-Light Manufacturing, Inc.

Accessories
Door

Yoke

Control
Handle

Clamp

Brake
Disk

Control

Handle

Tilt Lock

Lowel Prime LED is not a color mixing
LED system. There are dedicated
Tungsten and Daylight color models.

However, for optimal color balance of light out-
put, tungsten color models have a small qty of
daylight (C) LEDs, and daylight color models
have a small qty of tungsten (W) LEDs, integrat-
ed into the front panels.

The color temperature of each fixture can be
changed slightly (aprox 100-200 degrees K) by
changing settings in the in DMX mode. This may
help critical color balance to other light sources.
See Changing DMX Operation Mode, in the SET
Function section of this instruction sheet.

Clamp

Female 5/8"

Stand Fitting

Safety

Cable

Male Stud

(optional)

ver. 1.3 © Lowel-Light Mfg., Inc 2011

281

Tungsten Model

Code: PRM-200TU
Color Temperature:
3300˚K
Color Rendering Index: 91+
Weight: 13.5 lbs (6 kg)

Daylight Model

Code: PRM-200DA
Color Temperature:
5600˚K
Color Rendering Index: 91+
Weight: 13.5 lbs (6 kg)

Beam Angles: points at which intensity
drops to 50% of maximum.
Foot Candle readings taken with Tungsten
color model, at center of beam, using a Minolta
CL-200 meter.

14

.9

"

(3

8

cm

)

17.7" (44.9 cm)

15.5" (39.3 cm)

3.5" (8.9 cm)