Read all instructions and fully understand them before installing your TS Performance MP-8

module. Disconnect the battery terminals and remove keys from the ignition before installation.

Place Di-Electric Grease onto every electrical connection.












1. Locate a place to mount the MP-8 module inside the

engine compartment on the driver’s side where it will be
free from extreme heat and moisture. Use the supplied zip ties to securely mount the module.



2. Locate the Fuel Pressure Sensor on the driver’s side of the

engine block. On the DT466E, the connector is located
behind a computer beside the block. To access it simply
reach behind the computer and disconnect the plug. Then
plug our module into the male and female connections.

Locate the MAP Sensor on the top of the valve cover as in the
picture above. Disconnect the connections and plug our
module in-line. For Models with the MAP mounted on the
Firewall leave in a silver box. Leave Unplugged and only use
the ICP connectors


3. Route the wire from the adjustable switch through the

firewall to the module.


4. Mount the switch in the dash in a location the driver can

access easily.