Absolute maximum ratings, Recommended operating conditions, Electrical characteristics – Delta Electronics Multi-Rate CWDM SFP Transceiver LCP-1250 CWDM User Manual

Page 2

Advertising
background image

DELTA ELECTRONICS, INC.

2 2008/1/15

Rev. 0A

www.deltaww.com

Absolute Maximum Ratings

Parameter Symbol

Min.

Typ.

Max.

Unit

Note

Storage Temperature

Ts

-40

85

ºC

Supply Voltage

V

CC

0 5 V

Recommended Operating Conditions

Parameter Symbol

Min.

Typ.

Max.

Unit

Note

Case Operating Temperature

T

C

-5

70

ºC

1

Supply Voltage

V

CC

3.135

3.465

V

Data

Rate

1250 Mbps

Note 1: See order information

Electrical Characteristics

(V

CC

=3.3V

± 5%)

Parameter Symbol

Min.

Typ.

Max.

Unit

Note

Total Supply Current
LCP-1250D4xxxRB
LCP-1250D4xxxRBH
LCP-1250D4xxxRBT

I

CCT

360
380
380

mA

Transmitter

Transmitter Differential Input Voltage

V

DT

0.5 2.4 V

1

Transmitter Disable Input-High

V

DISH

2

V

CC

+0.3

V

Transmitter Disable Input-Low

V

DISL

Vee 0.8 V

Transmitter Fault Pull up Resistor

R

TX_FAULT

4.7 10 kΩ 2

Transmitter Fault Output-High

V

TXFH

2

V

CC

+0.3

V

Transmitter Fault Output-Low

V

TXFL

Vee 0.8 V

Receiver

Receiver Differential Output Voltage

V

DR

0.35

2

V

3

Receiver LOS Load

R

RXLOS

4.7 10 kΩ 2

LOS Output Voltage-High

V

LOSH

2

V

CC

+0.3

V

LOS Output Voltage-Low

V

LOSL

Vee 0.8 V

Output Data Rise/Fall Time

t

r

/ t

f

260

psec 4

Notes:
1. Internally AC coupled and terminated to 100Ohm differential load.

2. Pull up to V

CC

on host Board

3. Internally AC coupled, but requires a 100Ohm differential termination at or internal to Serializer/

Deserializer.

4. These are 20%~80% values

Advertising