TROUBLESHOOTING

Page 11

SYMPTOM: When controlling a Residential Heat
Pump, cooling energizes with a demand for
heat.
CAUSE: Heat pump is not selected "YES" in the
Advanced Setup.
REMEDY: See page 9 of the Owner's Manual
and configure step 4 to enable heat pump
operation.

SYMPTOM: When calling for cooling, both
the heat and cool come on.
CAUSE: The thermostat is configured to
control a heat pump and the HVAC
system is a "conventional" (non-heat
pump) system.
REMEDY: See page 9 of the Owner's Manual
and set step 4 to "NO” to enable gas
electric operation.