Serial configuration menu, Serial configuration menu -14, Notice – Verilink FrameStart FSM (34-00299.E) Product Manual User Manual

Page 132

Advertising
background image

5-14

F r a m e S t a r t F S M

Serial – Timing is derived from the Serial port recovered clock.

Zero Suppression

Determines whether ones density insertion is activated after 15 zeros. This
parameter is ignored if the Coding parameter is set to “B8ZS”.

Values: Disable, Enable
Default: Disable

PRM

Lets you establish which performance messaging standard will be employed
to initiate Performance Report Message (PRM) functions. Setting this field to
“Enable” instructs the unit to use ANSI T1.403, which sends a PRM once
every second. Setting this field to “Disable” instructs the unit to use AT&T
TR54016, which provides performance reporting on request only.

Values: Disable, Enable
Default: Disable

Serial Configuration Menu

The SERIAL INTERFACE lets you view and make changes to the unit’s
serial interface configurations.

Figure 5.13

Serial Configuration Menu Tree

Use the SERIAL CONFIG to set the configuration parameters defined in the
following paragraphs.

Type

This parameter selects the type of interface (based on its electrical signal
characteristics) used by the equipment connected to the Serial port.

Values: V.35, RS-232, EIA-530
Default: V.35

NOTICE:

V.35 requires the use of an optional cable. Refer to "Optional
Equipment"
for ordering information.

V.35

RS-232

EIA-530

Type

Mode

DSR

DCD

CTS

RTS

RTS Delay

Tx Clock

DCE
DTE

True

False

Int

True

False

Int

True

False

In*

Normal

True

Normal

Long

Int

Ext

Nx56
Nx64

(N = 1–32)

Channel

Rate

Rate

Inv Clock

Bundling

Start

Channel

No. of

Channels

V.54

LL

DTR Ctrl

Nx64K
Nx56K

Cont

Alt

1–24

1–24

Dis

En

Dis

En

Dis

En

Dis

En

Serial

Configuration

Advertising