Ds1 mib interface – Verilink SNMP Management (No Part Number) Product Manual User Manual

Page 5

Advertising
background image

SNMP Management

Verilink SNMP

SNMP-5

DS1 MIB Interface

Tables 4 through 10 list the various MIB-II interface parameters.
The accompanying comments explain the parameters, describe
specific conditions, or specify which parameters are not supported.

DS1 Near End

Group

Table 4 DS1 Near End Group 1

Object-Type

Parameters

dsx1LineIndex

A number calculated with the formula in

Calculating

the

SNMP

ifIndex

,

on page 2.

dsx1IfIndex

A unique number.

dsx1TimeElapsed

The number of seconds that have elapsed since the

beginning of the current error-measurement period.

dsx1ValidIntervals

The number of previous intervals for which valid

data was collected. The value is 96 unless the

interface was brought on-line within the last 24

hours, in which case the value will be the number of

complete 15 minute intervals the interface has been

online.

dsx1LineType

Access is read-only and applies to network side.

other(1) for any line type not defined in this object.

dsx1ESF(2) for ESF framing.

dsx1D4(3) for D4 framing.

dsx1E1(4) for G.704 framing (Table 4a).

dsx1E1_CRC(5) for G.704 framing (Table 4b).

dsx1E1_MF(6) for G.704 framing with TS16

multiframing enabled (Table 4a).

dsx1E1_MF(7) for G.704 framing with TS16

multiframing enabled (Table 4b).

dsx1LineCoding

Access is read-only and applies to network side.

dsx1B8ZS(2) for B8ZS line coding.

dsx1HDB3(3) for HDB3 line coding.

dsx1AMI(5) for AMI line coding.

other(6) for any line coding not defined in this

object.

dsx1SendCode

Access is read-write:

• dsx1SendNoCode(1) if no test pattern is sent.
• dsx1SendQRS(5) if near end is sending QRSS test pattern.

• dsx1Send3in24Pattern(7) if near end is sending 3/24 test

pattern.

For “read”:

• dsx1SendOtherTestPattern(8) if sending a test pattern other

than those defined in this object.

For “write”:

• dsx1SendOtherTestPattern(8) sends a 1-in-8 test pattern.

dsx1CircuitIdentifier

Access is read-write.

Circuit name.

Advertising