Switch s4, High-speed dte pinout, Switch s6 – Verilink PRISM 3001 (Standalone) (CG) Configuration/Installation Guide User Manual

Page 2: Switch s8 (t1 dte), Address switch s5, S7 bit rates (kbps), Alarm relay, Bantam jacks, Top-edge view of the 3001

Advertising
background image

T

R

A

N

S

P

O

R

T

®

1051-2 Chassis Rear Panel Pinouts

Pin

T1 D/I

T1 NET

NMS IN

NMS OUT

Alarm /Power Net/Ext. Clk

1

Data Out

Data In

Not Used

Not Used

48 V Return

Net In (Tip)

2

Data Out

Data In

Signal Ground

Signal Ground

Signal Ground Net In (Ring)

3

Not Used

Not Used

Data Out

Data Out

-48 VDC

Net Out (Tip)

4

Data In

Data Out

Data In

Not Used

Frame Ground Net Out (Ring)

5

Data In

Data Out

Signal Ground

Signal Ground

Alarm Contact Station Clk (Ring)

6

Not Used

Not Used

Not Used

Not Used

Alarm Common Station Clk (Tip)

7, 8

Chassis Ground Chassis Ground Not Applicable Not Applicable Not Applicable Not Applicable

1

61

1

1

6

1

8

1

8

NMS IN

6

NMS OUT

T1 D/I

NETWORK

1

14

13

25

DTE

PORT

48 VDC

ALARM/POWER

NTWK/EXT CLK

Switch S4

S4- 1: Network Framing

Dn: ESF

Up: D4

S4- 2: Network Coding

Dn: AMI

Up: B8ZS

S4-5: Channel Assignment - Used to
select DS0 channels (used with Switch
S7). See Table S7 Bit Rates (kbps).

S4- 8: Channel Assignment - Used to
select channel assignment mode (used
with Switch S7).

Dn: Contiguous Up: Alternate

S4 -3

S4 -4

Network LBO

Dn

Dn

0 dB

Up

Dn

-7.5 dB

Dn

Up

-15.0 dB

Up

Up

-22.5 dB

S4 -6

S4 -7

Timing Source

Dn

Dn

Internal Settings

Up

Dn

Network

Dn

Up

T1 DTE

Up

Up

High-speed port

8

6

5

4

3

2

1

D

n

U

p

7

127 Jetplex Circle

Madison, Alabama 35758

Sales and Marketing

800-926- 0085

205-772-3770

[email protected]

Returns/RMA

800-926-0085, ext. 2227

Technical Support

800-285- 2755
205-772- 3770

[email protected]

High-speed DTE Pinout

DB-25
25 - pin
A/B

Common

Name

EIA-530
25 - pin
A/B

RS-449
37-pin
A/B

V.35
34-pin
A/B

1

Frame Ground 1

1

A

7

Signal Ground 7

19

B

2 /14 Transmit

Data

2 /14 4/22

P/S

3/16 Receive

Data 3 /16

6/24

R /T

4/19

Request to
Send

4/19

7/25

C

5/13

Clear to Send

5/13

9/27

D

6/22

Data Set
Ready

6/22

11/29

E

20/23

Data Term
Ready

20/23

12/30

H

8/10

Data Carrier
Detect

8/10

13/31

F

15/12

Transmit
Clock

15/12

5/23

Y/AA

17/9

Receive Clock 17/9

8/26

V/ X

24/11

Terminal
Timing

24/11

17/35

U/ W

Switch S6

S6- 7: Used to set the multiplier with
Switch S7.

Dn:

×64

kbps

Up:

×56

kbps

S6- 8: Not used.

S6-1

S6- 2

NMS Port Rate

Dn

Dn

19200 bps

Up

Dn

9600 bps

Dn

Up

2400 bps

Up

Up

1200 bps

S6- 3

S6- 4

SUPV Port Rate

Dn

Dn

19200 bps

Up

Dn

9600 bps

Dn

Up

2400 bps

Up

Up

1200 bps

S6- 5

S6- 6

Power-up Mode

Dn

Dn

Switch Settings

Up

Dn

RAM

Dn

Up

Network Manager

Up

Up

ROM

8

6

5

4

3

2

1

D

n

U

p

7

Switch S8 (T1 DTE)

If equipped, this board is located on
the opposite side of the circuit board
shown in Figure Top-edge View of the
3001.
S8- 1: Used to set the line framing.

Dn: ESF

Up: D4

S8- 2: Used to set the line coding.

Dn: AMI

Up: B8ZS

S8- 6, S8-7, and S8- 8: Not used.

S8 -3 S8 - 4 S8 -5 DTE LBO

Dn

Dn

Dn

0 - 110 ft

Up

Dn

Dn

110 - 220 ft

Dn

Up

Dn

220 - 330 ft

Up

Up

Dn

330 - 440 ft

Dn

Dn

Up

440 - 550 ft

Up

Dn

Up

550 - 655 ft

Dn

Up

Up

>655 ft

8

6

5

4

3

2

1

D

n

U

p

7

8

6

5

4

3

2

1

Dn

Up

7

1

2

4

8

16

32

64

128

Binary values

0

0

0

0

0

0

0

0

LSB

MSB

Address Switch S5

For reference, all DIP
switches are provided with
upper and lower boxes to
check the particular user
selection. Factory default set-
tings are shown underlined.

S7 Bit Rates (kbps)

Switch
S7

w/S4- 5 down

w/S4-5 up

×56

×64

×56 ×64

0

56

64

168

192

1

112

128

280

320

2

224

256

392

448

3

336

384

448

512

4

560

640

504

576

5

672

768

616

704

6

1008

1152

728

832

7

1120

1280

784

896

8

1232

1408

896

1024

9

1344

1536

1064

1216

20 of the 24 possible bit rate configura-
tions are available through Switch S7
(and Switch S4). The missing rates are
N

×

56 and N

×

64, where N =15, 17, 21,

and 23. All 24 rate configurations are
available through software control.

This 3 -pin header straps the ACO alarm
contact. Position jumper over pins 1 and
2 for normally open operation (closes on
alarm) or over pins 2 and 3 for normally
closed operation (opens on alarm).

NO

NC

1
2
3

Alarm Relay

Top-edge View of the 3001

0

1

2

3

4

5 6

7

9

8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

Alarm

S5

S4

S6

S7

Bantam Jacks

Receive signal from

the network

Monitor signal from

the network

Transmit signal
to the network

Monitor signal
from the DTE

Four front panel bantam test jacks are
provided for access to the T1 line on
the DTE side of the CSU. Two are used
for non-intrusive bridge monitoring of
the line in both directions (MON) and
two are used to insert into the line in
both directions (NET).

Advertising
This manual is related to the following products: