Vinpower Digital Titan Lightscribe Autoloader User Manual

Page 40

Advertising
background image

38

Setup
11.Disable Drives

Save Changes?

Drive 1 Port 1.0
[*]Enable [ ]Disable

Drive 1 Port 1.0
[ ]Enable [*]Disable

Setting Saved!

Please Restart

Setup
10.ISRC

ISRC

On

ISRC
Off

Setup
12.Overburn

Overburn
On

Overburn
Off

Use the Up or Down button to select the ISRC menu
and press the ENT/Enter button to enter that menu.



Use the Up or Down button to select whether the
ISRC is ON or OFF, and press the ENT/Enter button to
select that option.


13.11 Disable Drives

This feature allows you to disable certain drives/trays when those drives/trays are producing high failure
rates or not functioning properly.


Use the Up or Down button to select the Disable Drives menu and
press the ENT/Enter button to enter that menu.

Use the

Up or

Down button to select the desired drive/trays you would

like to enable/disable. Then press ENT/Enter or ESC/Escape button to
move the asterisk in front of “Enable” or “Disable”.


Use the Up or Down button until you see the “Save Changes” screen
and press the ENT/Enter button to save the changes you made.


Once the changes are saved, you shall see the “Please Restart” screen and
restart the system to have the new setting take effect.


13.12 Overburn

Overburn is a burning method to bypass the capacity limitations of the media to burn further out onto the
edge of the media. This can result in slightly higher storage capacity; however, it has also been known to
have compatibility playback issues. Please use it with caution.

Note: This works only for CD and BD media. Due to physical limitations of the DVD media, it is not

possible to record more than the advertised capacity.


Use the Up or Down button to select the Overburn menu and press
the ENT/Enter button to enter that menu.

Use the Up or Down button to select whether the Overburn feature is
ON or OFF, and press the ENT/Enter button to select that option.



13.13 Max Failure per Job

Use this setting to set the maximum failures the autoloader is allowed per job. Once the maximum is
reached, the job will be stopped. The default value for this setting is 30.