Initial installation – Enviro Haven Direct Vent Fireplace User Manual

Page 19

Advertising
background image

19

KIT COMPONENTS:

Qnty

Description

Qnty

Description

1

Horizontal direct vent termination cap

4

Wire spacers

1

Flue collar adapter

1

4 oz tube Mill-Pac Sealant

1

Wall thimble

1

4 oz tube RTV silicone

1

5’ (190 cm) length of Ø4” (10 cm) double walled flex pipe

12

9

/

16

” tech screws

1

5’ (190 cm) length of Ø65⁄8” (10 cm) double walled flex pipe

8

11⁄2” wood screws

Please ensure that all components are supplied with this kit. If components are missing or have

been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if

components are missing or damaged.

INSTALLATION INSTRUCTIONS:
1. Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet

any or all local code requirements. Refer to the sections in your owner’s manual on where to locate

your stove.

2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing

pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location

should be adjusted if obstructions are found in the wall.

3. Project a line from the center point of the flue outlet upward and outward to the desired flue outlet

location on the exterior wall. Using this center point, scribe a 10” (25.4 cm) hole or square on the wall.

Please read and understand these instructions before installing. Failure to follow

these instructions carefully could cause property damage or personal injury.

����

�������

Figure 28: Wire Spacers.

Cut the hole out on both the interior and exterior wall surfaces.

4. Frame the hole as shown in Figure 32.
5. Trim the Wall Thimble to match the wall thickness as necessary. Install the

wall thimble and secure it to the inner wall frame using four (4) 11⁄2” wood

screws.

6. Apply a bead of Mill-Pac Black sealant to the new Ø4” (10 cm) by 5” (12.5

cm) provided flue collar adaptor. Press the flue collar into the flue outlet of

Initial Installation

QUALIFIED INSTALLERS ONLY

F

IREPLACE

H

ORIZONTAL

V

ENT

K

IT

50-1235:

Figure 29: Wire Spacer in Place.

the fireplace so that the Mill-Pac seals the

flue collar to the flue outlet.

7. Stretch both the Ø4” (10 cm) flex vent and

the Ø65⁄8” (16.25 cm) flex intake liner to

the length needed to ensure the flex can be

easily connected to the vent terminal.

8. Slide the Ø65⁄8” (16.25 cm) flex intake liner

over the flex vent. Install four (4) wire

spacers around the flex pipe. Ensure the

wire spacers are positioned at either end of

the pipes, and at each end of any elbows in

the liners (refer to Figure 28 and 29).