INSTALLATION

23

5

INSTALLATION

5.1

Unpacking

When unpacking, carefully follow the instructions as
given on the packaging or on the hose pump. This also
applies to the unpacking of the geabox and the electric
motor.

5.2

Inspection

Check that your delivery is correct and check it for any
transport damage. Also when replacing parts, check
that the delivery of the replacement parts is correct and
check them for any transport damage. See §

4.1.1

.

Report any damage immediately to your Bredel
representative.

5.3

Installation conditions

5.3.1

Ambient conditions

Temperature
Make sure that the hose pump is in an area where the
ambient temperature during operation is not lower than
-20 °C (-4 °F) and not higher than +45 °C (+113 °F).
The minimum start-up temperature for the gearbox is
-10 °C (+15 °F). A heater is required for tempertures
below -10 °C (+15 °F).
Note that some motors may not be suitable for this
entire range of temperature. Consult your motor
manufacturer’s documentation for suitability of the
motor in your ambient conditions.

Atmospheric humidity
When the unit must be stored for a long period of time,
especially in humid conditions, fill the gearbox
completely with oil and protect the machined parts with
rust inhibitors.