Watson-Marlow SPS User Manual

Page 80

Advertising
background image

MasoSine SPS sinusoidal pumps User Manual

80

l Pull the front liner to remove it.

Note: You may find it convenient to turn the pump shaft and rotor a little to create
space for your fingertips to grasp the top of the front liner.

Removing the front liner

It is important to ensure that the shaft cannot rotate while the shaft locking screw
and the shaft nut are removed. It may be convenient to secure it using a well-padded
wrench on the shaft and the key or keyway. A blocking tool for the shaft is option-
ally available for easy opening of the locking screw SPS 250: TL-SP21-010-31, SPS
300: TL-SP25-010-31, SPS 400: TL-SP40-010-31 and SPS 500: TL-SP50-010-31)

l Use the 42mm ring spanner supplied with the pump to remove the locking

screw from the shaft (left-hand thread).

l Use the 42mm ring spanner supplied with the pump to remove the shaft nut

from the shaft (right-hand thread). It will leave the shaft with the front sup-
port.

l You can now access the rotor front O-ring (arrowed) in its groove in the rotor

front.

Removing the shaft locking screw and the shaft nut

SPS 250, SPS

300, SPS 400

and SPS 500

pumps

Advertising