Service setting sample call flow, Ervice, Etting – Welltech SIPPBX 6200 V.3.1.0 User Manual

Page 146: Ample, Service setting flow, Welltech computer co., ltd

Advertising
background image

Welltech Computer Co., Ltd.

SIPPBX 6200S/GS Release 3.1.0 User Guide

- 146 -

Service Setting Sample Call Flow:

Service Setting Flow

Not Extension go to

Extension go to

Collect Success

1~7"

Collect Failed

False

Other

(1020)

True

Jump to

01,02, 11,12,

21,22, 31,32

Jump to

41,42,51,52
61,62,71,72

Other

Service Setting Begin

(1000)

(1016)

Prompt

Play Retry

prompt

Other

Variable Operation

Set IntCom6=0

(1052)

Variable Operation

Set StrCom1 to

empty

Prompt

Play Service
Setting Title

(1001)

End

(1012)

(1013)

Prompt

Play Caller out

of scrope

Variable Branch

Digit “1~7"and

*"

(1032)

(1002)

Prompt and Collect Digits

Play main menu and collect
user choice of which sevice

Prompt

Play over retry

and say bye

(1017)

End

(1018)

Variable Operation

IntCom6 plus 1

(Error count +1)

(1014)

Prompt

Play Input error

(1019)

If

intCom6>3

(over error retry

time)

(1015)

*

(1023)

Variable Operation

Store Digit into

StrCom1,

Set IntCom6=0

(1024)

Prompt and Collect Digits

Play sub-menu and collect

disable or enable service

Collect Success

1,2"

False

True

(1035)

Variable Operation

Store Digit into

StrCom1

Collect Failed

Other

If

intCom6>3

(over error retry

time)

(1037)

Prompt

Play over retry

and say bye

(1038)

End

(1039)

Prompt

Play Input error

(1040)

Variable Operation

IntCom6 plus 1

(Error count +1)

(1036)

Variable Branch

Digit “1,2"and

#"

(1003)

#

(1026)

Variable Branch

StrCom1 contains

01,02, 11,12, 21,22,

31,32

Variable Branch

StrCom1 contains

41,42,51,52,61,62,

71,72

(1041)

(1025)

Jump to 1052

Advertising