6614-2210

Interface specifications

Power

Rated voltage

12 to 48 VDC

Operating voltage

10 to 60 VDC

Rated current

130 mA @ 12 VDC
63 mA @ 24 VDC
40 mA @ 48 VDC

Rated frequency

DC

Power consumption

2W

Inrush current l

2

t

6 mA

2

S

Startup current

0.22 A

peak

Polarity

Polarity dependent

Connection

32-pin Europe connector

LED indicators

LED

Status

Indication of

RTS

OFF

RTS signal is inactive

ON

RTS signal is active

RD

OFF

No data

FLASH

The modem transmitting data on the DTE interface

TD

OFF

No data

FLASH

The modem receiving data on the DTE interface

DCD

OFF

DCD signal is inactive

ON

DCD signal is active, modem has detected a carrier or the signal is
set to always on

REL

OFF

Reliable mode is off, direct or normal mode

ON

Reliable mode is on

FLASH

Reliable mode with error correction and compression

LINE

OFF

The modem is on-hook

ON

The modem is off-hook with a established connection

FLASH

Line backup interface in use

PWR

OFF

The modem has no power

ON

The modem is up and running

FLASH

The modem is in the power-on selftest

Advertising