Type tests and environmental conditions – Westermo AD-01 User Manual

Page 6

Advertising
background image

6

6612-2202

Type tests and environmental conditions

Electromagnetic Compatibility

Phenomena

Test

Description

Level

EsD

EN 61000-4-2

Enclosure contact

± 4 kV

Enclosure air

± 8 kV

RF field AM modulated

IEC 61000-4-3

Enclosure

10 V/m 80% AM (1 kHz), 80 - 2700 MHz

Fast transient

EN 61000-4-4

signal ports

± 1 kV

Power ports

± 2 kV

surge

EN 61000-4-5

signal ports unbalanced

± 1 kV line to earth, ± 1 kV line to line

signal ports balanced

± 1 kV line to earth, ± 1 kV line to line

Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted

EN 61000-4-6

signal ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Voltage dips and
interruption

EN 61000-4-11

AC power ports

10, 20 & 5000 ms, interruption
200 ms, 60% reduction
500 ms, 30% reduction

Radiated emission

EN 55022

Enclosure

Class B

Conducted emission

EN 55022

AC power ports

Class B

Dielectric strength

EN 60950

signal port to all other
isolated ports

2 kVrms 50 Hz 1min

Power port to other
isolated ports

3 kVrms 50 Hz 1min
2 kVrms 50 Hz 1min (@ rated power < 60V)

Environmental

Temperature

Operating

–0 to +50°C

storage & Transport

-25 to +70°C

Humidity

Operating

5 to 95% relative humidity

storage & Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

service life

Operating

10 years

Vibration

IEC 60068-2-6

Operating

7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz

shock

IEC 60068-2-27

Operating

15 g, 11 ms

Packaging

Enclosure

uL 94

PC / ABs

Flammability class V-1

Dimension W x H x D

55 x 100 x 128 mm

Weight

0.9 kg

Degree of protection

IEC 529

Enclosure

IP 20

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail

Advertising