Westermo DDW-225-EX User Manual

Page 10

Advertising
background image

10

6642-22313

Ratings

Power

(20 – 48) VDC; 330 mA

Ambient temperature

–40ºC ≤ Ta ≤ +70ºC

Ingress protection (IP)

IP40

Maximum surface temperature

135ºC (temperatur class T4)

Safety Control Drawing

Degree of protection

IP40

Ambient temperature

–40°C to +70°C

Installation spacing

Minimum 25 mm above / below
Minimum 10 mm left / right

Direction relative this unit!

Position

Direction*/

descripton

Input/Output
values

1

In/Out / SHDSL

U = ± 15 Vpk
I = ± 25 mA
Data rate
up to
15.3 Mbit/s

2

In/Out / SHDSL

* Galvanically isolated via signal transformer

and capacitively isolated to signal ground

through a 1.5 kV 220 pF capacitor.

See user manual for proven transient pro-

tection.

Position

Direction*/
description

Input/Output
values

1
2
3
4

1

IO / Relay output + U

in

= 60 VDC max

U

in

= 80 mA max

2

IO / Relay output –

3

IO / Digital in +

U

in

= 60 VDC max

U

in

= 10 mA max

4

IO / Digital in –

M5 threaded hole
for PE connection.

Position

Direction/
descripton

Input/Output
values

1

In/out / GND

U = 3.3 VDC max
I = 24 mA max

2

Out / Tx

3

In / Rx

Position

Direction*/

descripton

Input values

1

In / +Voltage A

U

in

= (16 – 60) VDC

I

in

= 420 mA @ 16 VDC

P

In

= Max 7 W

2

In / +Voltage B

3

In / Common

4

In / Common

* See section Type tests and environmental conditions in this user

manual for proven transient protection.

Position

Direction/

descripton

Input values

1

Out / VBUS

U

out

= 5 VDC max

I

out

= 500 mA max

2

In/out / D–

3

In/out / D+

4

GND

Shield

PE

Position

Direction*/

descripton

Input/Output values

1

In/Out / TD+

U = ± 1 V (4μV/s)
I = ± 20 mA
Data rate: 10/100 Mbit/s

2

In/Out / TD–

3

In/Out / RD+

4

Not connected

5

Not connected

6

In/Out / RD–

7

Not connected

8

Not connected

Shield

PE

* Galvanically isolated via signal transformers and capacitively

isolated to signal ground through a 2 kV 1000 pF capacitor.

See user manual for proven transient protection.

Advertising